ECR International G95V Installation Manual And Operating Instructions page 52

Natural and propane gas two stage high efficiency (condensing) warm air furnace
Table of Contents

Advertisement

A RED LED is provided to indicate furnace operating status
LED Condition
Fault Condition
6 Flashes
Not Used
7 Flashes
Pressure switch cycle
lockout
8 Flashes
Lockout due to too many
flame dropouts
9 Flashes
Not used
10 Flashes
Flame present with gas off
A GREEN LED is provided to indicate high heat state
LED off
No demand for high heat
LED on
High heat demand, operating normally
LED flashing
High heat demand, high pressure switch not closed
FAULT CODE HISTORY
The control stores the last 5 fault codes in memory.
When the pushbutton switch is pressed for less
than 5 seconds, the control will flash the stored
fault codes when the switch is released. The most
recent fault code is flashed first, the oldest last.
Fault history may be cleared by holding the push-
button switch for more than 5 seconds.
DIAGNOSTIC CODES FOR STATUS LED
Check
Pressure switches operation, tubing and wiring.
Obstruction or restrictions in venting preventing
proper air flow.
Check system for proper ground.
Dirty, oxidized or failed flame sensor.
Flame at main burner.
Gas valve.
52