ECR International GTM Series User's Information Manual

Gasfired warm air furnace.

Advertisement

Quick Links

THESE INSTRUCTIONS
APPLY TO THE
MODEL GTM SERIES GAS-
FIRED WARM AIR
FURNACE.
USER'S INFORMATION
This symbol indicates important Safety Related Information
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury death or
property damage.
ð Do not store or use gasoline or other flamma-
ble vapors and liquids in the vicinity of this or
any other appliance.
ð WHAT TO DO IF YOU SMELL GAS:
· Do not try to light any appliance.
· Do not touch any electrical switch; do not use
any phone in your building.
· Leave the building immediately.
· Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
· If you cannot reach your gas supplier, call the
fire department.
ð Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
DO NOT DESTROY THIS MANUAL
Please read this manual completely and keep in a safe place for
future reference.
MANUAL
29785 R3 3/10/2004

Advertisement

Table of Contents
loading

Summary of Contents for ECR International GTM Series

  • Page 1 USER’S INFORMATION MANUAL This symbol indicates important Safety Related Information THESE INSTRUCTIONS APPLY TO THE MODEL GTM SERIES GAS- FIRED WARM AIR FURNACE. FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage.
  • Page 2: Safety Issues

    SAFETY ISSUES WE, THE MANUFACTURER IMPORTANT: CANNOT AND WILL NOT SPECULATE ON THE EFFECTS OF READ THESE INSTRUCTIONS IMPROPER INSTALLATION, SUCH MODIFICATIONS, AND THOROUGHLY BEFORE ADJUSTMENT, ALTERATION, CANNOT AND WILL NOT BE ATTEMPTING TO OPERATE THIS SERVICE OR MAINTENANCE CAN RESPONSIBLE FOR INJURY OR FURNACE.
  • Page 3: General Safety Rules

    FIGURE 2: GAS REGULATOR VENT supplying combustion or ventila- furnace and to replace all gas con- tion air to the area where the fur- trols, control system parts, electri- cal parts that have been wet or the nace is installed. There are many areas from which your furnace furnace if deemed necessary.
  • Page 4: Furnace Operation Information

    FURNACE OPERATION INFORMATION During the heating season, the opera- Simply turn the thermostat down to its tion of the furnace is fully automatic. lowest setting, wait 5 minutes, then adjust the thermostat to the desired TO START THE FURNACE: NEVER USE TOOLS TO TURN THE setting.
  • Page 5: Maintenance

    Figure 4: Honeywell Valve Figure 5: White-Rodgers Valve MAINTENANCE ROUTINE MAINTENANCE BY REMOVING FILTER Figure 6: Side Positioned Filter HOMEOWNER Disconnect electrical power to the furnace. AIR FILTER Pull the filter out the front. Clean or replace the O NOT OPERATE YOUR FURNACE OR AIR filter, then re-install CONDITIONER...
  • Page 6: Routine Examination

    FURNACE APPEARANCE The furnace exterior finish is a durable automotive like coating. It may be F CLEANING RATHER THAN REPLACING THE O NOT OVER OIL THE ELECTRIC MOTOR washed with mild soap if necessary. FILTER UNLESS THE FILTER IS THOROUGHLY XCESS OIL WILL SHORTEN THE LIFE OF THE Galvanized metal surfaces require no WASHED AND DRIED...
  • Page 7: Sequence Of Operation

    SEQUENCE OF OPERATION Thermostat, responding to cool room, calls for heat. HE FURNACE SHOULD BE OPERATED WITH ALL PANELS IN PLACE EVER OPERATE THE Combustion air blower begins. FURNACE WITH BLOWER DOOR After 15 second pre-purge, hot REMOVED EXCEPT FOR SERVICE PURPOSES surface igniter warms up.
  • Page 8 Home Owner Information To help remember important information, Please fill in the chart below: Model No.: Serial No.: Installer: Address: City: Postal Code: Telephone Numbers Installer: Serviceman: After Hr. Phone: Fuel Supplier: 6800 Base Line, Wallaceburg, Ontario, N8A 5E5, Can. Tel: (519) 627-0791 Fax: (519) 627-4719 2201 Dwyer Avenue, Utica, New York, 13504, USA.