TABLE 3 - HEATING CFM
95V060-3
HEAT
ADJUST
Jumper
Jumper
A
NORM
B
NORM
C
NORM
D
NORM
95V080-4
HEAT
ADJUST
Jumper
Jumper
A
NORM
B
NORM
C
NORM
D
NORM
95V120-5
HEAT
ADJUST
Jumper
Jumper
A
NORM
B
NORM
C
NORM
D
NORM
* Motor CFM maxium
95V080-3
HEAT
ADJUST
Jumper
Jumper
A
NORM
B
NORM
C
NORM
D
NORM
* Motor CFM maxium
ESP 0.1" to 1.0" w.c.
Low-Fire
High-Fire
CFM
CFM
700
1050
850
1105
575
880
525
819
ESP 0.1" to 1.0" w.c.
Low-Fire
High-Fire
CFM
CFM
1000
1350
1150
1495
900
1206
800
1104
ESP 0.1" to 1.0" w.c.
Low-Fire
High-Fire
CFM
CFM
1650
2200*
1900
2200*
1500
2070
1325
1815
ESP 0.1" to 1.0" w.c.
Low-Fire
High-Fire
CFM
CFM
1050
1376
1250
1400*
900
1242
780
1108
95V100-5
HEAT
ADJUST
Jumper
Jumper
A
NORM
B
NORM
C
NORM
D
NORM
Note: Moving the ADJUST jumper from the NORM position to the
(+) or (-) position will increase or lower the temperature rise
by 15%
If the blower speeds require adjustment, follow
these steps:
1. Remove the blower compartment door.
2. Locate the 4 position movable HEAT jumper
to adjust heat speed.
3. Remove the jumper from position A
and place it on the corresponding letter B, C,
or D as required. Refer to TABLE 2 - HEATING
SPEEDS.
NOTE: Temperature rise should always be re-checked
whenever blower speed is changed.
4. To adjust the cooling airflow, remove
the COOL jumper from position A and place
it on the corrosponding letter B, C, or D. Refer
to TABLE 10 AIR FLOW.
Moving the ADJUST jumper from the NORM to
the (+) or (-) position will cause the airflow to be
increased or lowered by 15%.
The TEST position on the ADJUST tap is not
used.
DEHUMIDIFICATION:
For situations where humidity control is a problem,
a dehumidification feature has been built into the
variable speed motor. At the start of each cooling
cycle, the variable speed motor will run at 82% of
the rated airflow for 7.5 minutes. After 7.5 minutes
has elapsed, the motor will increase to 100% of the
rated airflow. If this feature is not desired, clip the
jumper wire between Y and O on the integrated fur-
nace control board. With Y and O not jumpered, the
variable speed will reach 100% of the rated airflow
within 10 seconds of a call for cooling.
46
ESP 0.1" to 1.0" w.c.
Low-Fire
High-Fire
CFM
CFM
1200
1620
1400
1820
1100
1474
950