Switching Logic - Siemens sitrans LVS200 Instruction Manual

Standard vibrating level switch for use in all liquid and slurry applications
Hide thumbs Also See for sitrans LVS200:
Table of Contents

Advertisement

Available languages

Available languages

Switching Logic

Probe uncovered
Model
SPDT relay
DPDT relay
3-wire PNP
2-wire
8/16 mA
Signal Output LED
NAMUR IEC 60947-5-6
Signal Output LED
Probe covered
Model
SPDT relay
DPDT relay
3-wire PNP
2-wire
8/16 mA
Signal Output LED
NAMUR IEC 60947-5-6
Signal Output LED
7ML19985FT62
Signal Output
Failsafe low
3 4 5
I = 16 mA
Low alarm setting
I < 1 mA
Signal Output
Failsafe low
3 4 5
I = 8 mA
Low alarm setting
I >2.2 mA
SITRANS LVS200 – INSTRUCTION MANUAL
Failsafe high
3 4 5
I = 8 mA
High alarm setting
I > 2.2 mA
Failsafe high
3 4 5
I = 16 mA
High alarm setting
I < 1 mA