8.2

CS-PC18QKH CU-PC18QKH

Resistance of Indoor Fan Motor Windings
MODEL
Others/S. E. Asia
CONNECTION
BLUE-YELLOW
YELLOW-RED
Note: Resistance at 20°C of ambient temperature.
Resistance of Outdoor Fan Motor Windings
MODEL
Others/S. E. Asia
CONNECTION
CWA951688
BLUE-YELLOW
YELLOW-RED
Note: Resistance at 20°C of ambient temperature.
CS-PC18QKH
Myanmar
CWA921459
230 Ω
298 Ω
CU-PC18QKH
Myanmar
CWA951851
276 Ω
247 Ω
291 Ω
254 Ω
Resistance of Compressor Windings
MODEL
CONNECTION
C-R
C-S
Note: Resistance at 20°C of ambient temperature.
26
CU-PC18QKH
Others/S. E. Asia
Myanmar
2KS314D5CA06
2KS314D5BA06
2.298 Ω
1.853 Ω
3.223 Ω
4.879 Ω