Panasonic CS-PC12QKH Service Manual page 14

Hide thumbs Also See for CS-PC12QKH:
Table of Contents

Advertisement

Model
Height(I/D / O/D)
Dimension
Width (I/D / O/D)
Depth (I/D / O/D)
Weight
Net (I/D / O/D)
Pipe Diameter (Liquid / Gas)
Standard length
Length range (min – max)
I/D & O/D Height different
Additional Gas Amount
Length for Additional Gas
Inner Diameter
Drain Hose
Length
Fin Material
Fin Type
Indoor Heat
Exchanger
Row x Stage x FPI
Size (W x H x L)
Fin Material
Outdoor
Fin Type
Heat
Row x Stage x FPI
Exchanger
Size (W x H x L)
Material
Air Filter
Type
Power Supply
Power Supply Cord
Thermostat
Protection Device
Indoor Operation Range
Outdoor Operation Range
1.
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).
Specifications are subjected to change without prior notice for further improvement.
2.
Indoor
Outdoor
mm (inch)
mm (inch)
mm (inch)
kg (lb)
mm (inch)
m (ft)
m (ft)
m (ft)
g/m (oz/ft)
m (ft)
mm
mm
mm
mm
A
Maximum °C
Minimum °C
Maximum °C
Minimum °C
CS-PC28QKH (Others/S. E. ASIA)
CU-PC28QKH (Others/S. E. ASIA)
290 (11-7/16) / 750 (29-17/32)
1070 (42-5/32) / 875 (34-15/32)
240 (9-15/32) / 345 (13-19/32)
12 (26) / 62 (137)
6.35 (1/4) / 15.88 (5/8)
5.0 (16.4)
3 (9.8) ~ 30 (98.4)
20 (65.6)
30 (0.3)
7.5 (24.6)
12
550
Aluminium (Pre coated)
Slit Fin
2 x 15 x 21
810 x 315 x 25.4
Aluminium (Blue coated)
Corrugate Fin
2 x 28 x 19
44 x 711.2 x 836.9
Polypropelene
One-touch
Outdoor
20
Mechanical
DRY BULB
32
16
43
16
14
-
WET BULB
23
11
26
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents