3. Name and Setting of Each Part
The name of each part in the AJ65BT-64DAV/DAI is described.
3.1 Name of each part
No.
Name
1)
Station number
setting switch
2)
B RATE
(transfer baud rate)
setup switch
3)
CH.(CHANNEL)
selection switch
4)
OFFSET/GAIN
(Offset/gain)
setting switch
5)
UP/DOWN switch
6)
RESET switch
MELSEC
A
J65BT-64DA
8)
X10
The AJ65BT-64DAV/DAI station number is set within
the range 1 to 63
X1
Setting number
0
1
2
3
4
Other than 0 to
Unused (When a value other than 0 to 4 is set, L ERR.
4
LED turns on, and results in a communication error.)
Select the channel to perform offset adjustment or gain adjustment.
(Positions other than 1 to 4 are not processed.)
The switch to set the offset/gain values during test mode.
(1) OFFSET position : Calibration mode for the offset value
(2) GAIN position
(3) SET position
The switch to adjust the analog output value for the offset/gain of the
specified channel. The analog output value increases/decreases by
turning on the UP/DOWN switch
Resets the H/W.
Initializes the AJ65-BT-64DAV/DAI I/O signals, remote register, and
operation processing. When the switch is turned on, the
AJ65BT-64DAV/DAI initial data processing request flag turns on.
2)
1)
BRATE
STATION NO.
X10
X1
0
0
0
1
1
9
1
2
2
8
2
PW
3
3
7
3
4
6
5 4
6
5 4
RUN
L RUN
CH. OFFSET UP
RESET
SD
1
RD
2
L ERR.
3
4
GAIN
DOWN
7)
3)
4)
5)
6)
Description
Transfer baud rate
156k bps(Factory shipment setting)
625kbps
2.5Mbps
10Mbps
: Calibration mode for gain
: When the switch is set from the OFFSET/GAIN
position, which are modes to record offset/gain
value to the SET position, to the SET position, the
offset/gain value is recorded.
5Mbps