Option - XP Metal Detectors Deus V4 User Manual

Hide thumbs Also See for Deus V4:
Table of Contents

Advertisement

G.B.
MANUAL
PUMPING
BEACH
TRACKING
START
~
15 cm (6")
If a metal target is detected while you are pumping, the Dēus will recognise this and display the
message " GB FAIL" It will then retain the previous ground balance value. This problem is generally caused
by iron being present. If this is the case then move to another location and restart the pumping
In low- or non-mineralised ground, there is no need to adjust the ground balance and you are
advised to remain on 90 for greater stability.
10 - GOLD FIELD

OPTION

MENU
SOL
Controlling via remote control
6 inches
~
15 cm
Controlling via the headphone
GND
DISC
SENS
TONE
GND
VOL
FREQ
COIL
6 inches
~
15 cm
14
GROUND
Go to Pumping with
Press
 and pump the coil on the ground
START
several times until you obtain the display G.B OK
Exit with
Pumping is a semi-automatic process which allows you to adjust the ground
balance in a zone that you wish to search and have determined it as being an
overall average soil type. Henceforth, the measured value of the ground is
entered into the memory and used as the new active ground balance value.
If this value is unsuitable, or if it generates too much instability, you can repeat
the process in a different zone or switch to manual mode adding several extra
rejection points.
The program 10 GOLD FIELD is adapted specifically to search for gold nuggets in
mineralised soils or likely gold areas. These areas are difficult to prospect with
conventional detectors. The reason for this being the presence of ferromagnetic
metals, they hide gold nuggets. Program n°10 GOLD FIELD uses another
technique different from conventional detectors which cannot achieve an
accurate ground balance in such extreme conditions.
You have the possibility to ground balance using the remote control or the headphone.
Press
to grab the ground value while pumping the coil on the ground to
calibrate and stabilise the DEUS. The number on the lower right of the screen
shows you the new ground value.
Restart the operation if the ground changes or it becomes unstable.
Press
to reach Program (P1...), Select Program 10 (P 10) with
MENU
Press
to reach "GND".
MENU
Press
while pumping the coil on the ground to grab the ground value.
Restart the operation if the ground changes or it will becomes unstable
G.B.
MANUAL
G.B OK
BEACH
TRACKING
IN PROGRESS
or

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents