c. The result will be imported and reflect to each param-
eter.
• Press "Write to ROM" to write.
• Exit "LTabMonS" to finish.
7.2.1.
Precise calibration
1. Adjusting method.
a. Make sure the LTabMonS is not running. Start up the
"Touch Driver".
b. Start "LSaDrv Driver".
c. Select "Basic setting".
d. Press "Advanced" button.
e. Select
the
tab
"Advanced" button.
f. Press "precise calibration" button.
"precise calibration" dialog box will appear.
"Direction
setting"
and
g. Press "OK".
h. Touch the "X" marker in the top right corner (shown in
yellow) with the touch pen, and wait.
• When the driver capture XY coordinates, the yellow
"X" marker moves one to right. (The remainder sec-
ond to capture is displayed.)
• Capture XY coordinate for each "X" marker shown in
yellow. Get data from all 25 points.
i. When you finish collecting data from all points, the
calibration result will be asked. Then press "OK" to
exit.
2. Check for the calibrating result (test)
a. Exit "LSaDrv Driver", and touch any marker to test.
• Point positions should not be too far off. It should be
press
within 5 mm.
• In order to test, set the setting to 0 (zero) in the
"Allowance for point position differences" in the setup
panel of Touch Driver.
Refer to "Touch Panel Setup (Advanced setting)" of
"Setup Procedure".