Axxon Composites
Visual inspection for cracks, corrosion, fading.
Non-Destructive Testing (NDT) of Rod.
Dye penetrate testing (liquid penetration testing) by authorized professional.
X-ray, ultrasound testing.
Visually inspect and Safe Working Load pull test all fiber rigging.
Make repairs as needed (re-head rod, replace any fittings or rigging screws).
Reassemble mast system.
Update service log/update schedule for next service.
Re-step/re-tune mast.
st
nd
For the 1
and 2
categories you should do:
A level A inspection several times a year.
A level B inspection once per year, with a maximum of four years between inspection
intervals.
A level C inspection once every four years, with a maximum of ten years between
inspection intervals.
rd
th
For the 3
and 4
categories you should do:
A level A inspection several times per year.
A level B inspection at least once per year, with a maximum of two years between
inspection intervals.
A level C inspection once every two years with a maximum of four years between
inspection intervals.