Fluke 787 User Manual page 47

Processmeter
Hide thumbs Also See for 787:
Table of Contents

Advertisement

AC Current Measurement
Range
45 Hz to 2 kHz
1.000 A (Note)
Note: 440 mA continuous, 1 A 30 seconds maximum on, 5 minutes off
Specifications are valid from 5 % to 100 % of amplitude range.
AC conversion: true rms
Maximum crest factor: 3
For non-sinusoidal waveforms, add
Overload protection 440 mA, 1000V fast-blow fuse
DC Current Measurement
Range
30.000 mA
1.000 A (Note)
Note: 440 mA continuous, 1A 30 seconds maximum on, 5 minutes off
Overload protection: 440 mA, 1000V fast-blow fuse
info@Fluke-Direct.com
Accuracy, ±(% of Reading + Counts)
Resolution
0.001 A
±
(2 % reading + 2 % f.s.) typical
Accuracy, ±(% of Reading + Counts)
Resolution
0.001 mA
0.001 A
Fluke-Direct
1 % + 2
0.05 % + 2
0.2 % + 2
.com
1.888.475.5235
ProcessMeter™
Specifications
Typical Burden
Voltage
1.5 V/A
Typical Burden
Voltage
14 mV/mA
1.5 V/A
39