SECTION 5 – INSTRUCTIONS FOR USE
Using COSMIQ
to set Max Depth and/or Max Time alarms:
+
To set the Max Depth and Max Time alarms using COSMIQ
the MODE button. Once in Freedive Mode, press the ADJUST button to access the maximum
depth settings. The minimum is 15 meters/49 feet and the maximum is 80 meters/265 feet. Press the
ADJUST button repeatedly to achieve the desired depth. Each time you press ADJUST, the depth
will increase by 5 meters/16 feet. When you reach the desired depth, press the MODE button to
save your changes.
Next, press the ADJUST button to set the maximum time. Press the ADJUST button repeatedly to
achieve the desired time. The minimum is 30 seconds and the maximum is 3 minutes. Each time you
press ADJUST, the time will increase by 10 seconds. Press the MODE button to save your changes
and return to Freedive Mode.
You can hold the ADJUST button to toggle through the depth and time continuously.
5.4.3 Freedive Mode – During a Dive
Once pressure is detected, COSMIQ
buttons will be disabled for the duration of the dive. No settings can be changed and no other
modes can be accessed during the dive.
During a dive using Freedive Mode, the following information will be displayed:
-
Current depth
-
Dive time
-
Water temperature
During a dive, once you reach the depth set on your Max Depth alarm, the alarm will beep
continuously until you ascend above that depth.
When you reach the dive time set on your Max Time alarm, the alarm will sound for 6 cycles of 3
beeps per cycle.
5.4.4 Freedive Mode – Surface Interval
Upon surfacing from a dive in Freedive Mode, COSMIQ
Time. It will be displayed on the display screen in Freedive Mode and Watch Mode.
COSMIQ
will calculate a safe Surface Interval Time for you based on the profile of your last dive.
+
The Surface Interval Time is calculated according to a formula that is designed to ensure maximum
safety. The formula is as follows:
Surface Interval Time = (max depth / 10 + 1) x dive time
An alarm will sound halfway through the surface interval, as well as at the end of the surface interval.
For example, if you dove to 30 meters/99 feet for a total of 2 minutes, your safe Surface Interval Time
will be 8 minutes. The first alarm will sound 4 minutes after your dive. The second alarm will sound
after 8 minutes.
BACK TO INDEX
will lock into Freedive Mode. The MODE and ADJUST
+
+
28
, navigate to Freedive Mode using
+
will begin to count the Surface Interval