Product Overview
Indicator
Power subsystem
status LED
Status LED
Fan status
Location
Color
Front panel of
Off
chassis
Green
Red
Front panel of
Green
chassis
Orange
Red
Front panel of
Green
chassis
Red

Cisco MDS 9396S Multilayer Fabric Switch Hardware Installation Guide

Status
State
Off
Either of the following conditions
exists:
• The system is not receiving
sufficient power from the
PSUs.
• NXOS is not running.
Solid On
Both PSUs are installed and
operating
Solid On
A PSU has failed.
Solid On
All diagnostics have passed,
NX-OS is running and the system
is operational.
Solid On
Any of the following conditions
exists:
• The system is running
bootup diagnostics.
• The system is booting.
• A minor temperature
threshold is currently
exceeded.
Blinking
Unmatched airflow direction for
PSU/Fan tray.
Solid On
Any of the following conditions
exists:
• A diagnostic test failed or
another fault occurred
during bootup.
• A major temperature
threshold is currently
exceeded.
Solid on
Both fan modules are operational.
Solid on
Fan failure.