14. USEFUL ADVICE
Anticipate change to work phase without having to wait entire ignition cycle.
Keep key 5 pressed to change directly to work phase without having to wait entire ignition cycle. The flue gas
must have reached minimum temperature to change to work phase to deem stove ignited (Pr13). If not,
equipment does not change to work phase.
As equipment functioning must be checked in every work condition during first test, do not run the following
procedure during "Commissioning".
Anticipate a new equipment ignition without having to wait stand-by time during switch-off
phase.
New equipment ignition without having to wait execution of entire cooling cycle is possible during switch-off
phase; keep key 6 pressed for about 5 seconds and subsequently press key 4 to perform new ignition.
Flue gas intake device can be switched off in this way (intake device only switches off if flue gas temperature
is below value set on parameter Pr39). Proceed with new equipment ignition.
The wording "COOL- STAND-BY" ("COOLING STAND-BY")
new equipment ignition if previously described procedure is incorrectly executed.