klover AURA 80 Installation, Use, Maintenance And Helpful Tips

klover AURA 80 Installation, Use, Maintenance And Helpful Tips

Hide thumbs Also See for AURA 80:
Table of Contents

Advertisement

AURA 80,
ENGLISH
CLASS 90,
AURA 120,
REA 100
pellet-burning
stove
INSTALLATION, USE,
MAINTENANCE AND HELPFUL
TIPS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AURA 80 and is the answer not in the manual?

Questions and answers

Summary of Contents for klover AURA 80

  • Page 1 AURA 80, ENGLISH CLASS 90, AURA 120, REA 100 pellet-burning stove INSTALLATION, USE, MAINTENANCE AND HELPFUL TIPS...
  • Page 3 Ref. Annex III EU Regulation no. 305/2011 DoP/KLOVER-042 Identification number : A80, AC80, CL90, CLC90 AURA 80 AIR, AURA 80 MULTI-AIR, CLASS 90 AIR, Model and/or lot no. and/or serial no. (Art.11-4) CLASS 90 MULTI-AIR Intended use of the product according to the...
  • Page 4 Intended use of the product according to the : Wood pellet-fired domestic heating appliance relevant harmonised technical specification KLOVER s.r.l. Name or trademark of the manufacturer (Art11-5) I - 37047 San Bonifacio (VR) – Via A. Volta, 8 Name and address of the representative (Art.12-2)
  • Page 5 Intended use of the product according to the : Wood pellet-fired domestic heating appliance relevant harmonised technical specification KLOVER s.r.l. Name or trademark of the manufacturer (Art11-5) I - 37047 San Bonifacio (VR) – Via A. Volta, 8 Name and address of the representative (Art.12-2)
  • Page 6: Table Of Contents

    CLASS 90 ........................... 11 ONNECTIONS DATA SHEET AURA 120 .......................... 12 ONNECTIONS DATA SHEET REA 100 ..........................13 ONNECTIONS DATA SHEET AURA 80 – CLASS 90 ....................... 14 ECHNICAL PECIFICATIONS AURA 120 ......................... 15 ECHNICAL PECIFICATIONS REA 100 ..........................16...
  • Page 7 STANDARD WARRANTY CONDITIONS ......................... 58 Dear client, First of all we would like to thank you for choosing a “KLOVER” product and we hope you will be satisfied with this product. Please carefully read the warranty certificate on the last page of this User guide.
  • Page 8: Introduction

    - The installation and initial start-up of the appliance must be performed by skilled personnel trained in the relevant safety standards. They will be fully responsible for the definitive installation of the appliance and its proper operation. KLOVER srl shall not be held liable if these precautions are not observed.
  • Page 9: The Machine And The Pellets

    AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 KLOVER S.R.L. DECLINES ALL LIABILITY IN CASE OF ACCIDENTS DUE TO FAILURE TO COMPLY WITH THE SPECIFICATIONS OF THIS MANUAL. KLOVER S.R.L. DECLINES ALL LIABILITY DUE TO INCORRECT USE OF THE PRODUCT BY THE USER, UNAUTHORISED MODIFICATION AND/OR REPAIRS, AND USE OF NON-ORIGINAL SPARE PARTS OR SPARE PARTS NOT SPECIFICALLY DESIGNED FOR USE ON THIS PRODUCT MODEL.
  • Page 10 AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 VIEW FROM ABOVE Microswitch for Pneumatic arm for Airtight seal for tank. closing tank cover. raising the door. REAR VIEW Flue gas Intake pipe. outlet. Wi-Fi information (Mac address and Registration code).
  • Page 11: Overall Dimensions Aura 80

    AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 Overall dimensions AURA 80...
  • Page 12: Overall Dimensions Class 90

    AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 Overall dimensions CLASS 90...
  • Page 13: Overall Dimensions Aura 120

    AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 Overall dimensions AURA 120...
  • Page 14: Overall Dimensions Rea 100

    AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 Overall dimensions REA 100...
  • Page 15: Connections Data Sheet Aura 80

    AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 Connections data sheet AURA 80 REAR VIEW Description of connections C = Ducted air outlet (“MULTI-AIR” model only) 80 mm M A = Intake pipe 50 mm...
  • Page 16: Connections Data Sheet Class 90

    AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 Connections data sheet CLASS 90 REAR VIEW Description of connections C = Ducted air outlet (“MULTI-AIR” model only) 80 mm M A = Intake pipe 50 mm...
  • Page 17: Connections Data Sheet Aura 120

    AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 Connections data sheet AURA 120 Description of connections C1 = Ducted air outlet 1 (“MULTI-AIR” model only) 80 mm M C2 = Ducted air outlet 2 (“MULTI-AIR” model only)
  • Page 18: Connections Data Sheet Rea 100

    AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 Connections data sheet REA 100 REAR VIEW VIEW Description of connections A = Intake pipe 50 mm Sb = Rear Flue gas outlet 80 mm M...
  • Page 19: Technical Specifications Aura 80 - Class 90

    AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 Technical Specifications AURA 80 – CLASS 90 Nominal heat input kW (kcal/h) 8.51 (7,350) Reduced thermal capacity kW (kcal/h) 2.64 (2,300) Nominal thermal output kW (kcal/h) 7.81 (6,750)
  • Page 20: Technical Specifications Aura 120

    AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 Technical Specifications AURA 120 Nominal heat input kW (kcal/h) 12,1 (10.406) Reduced thermal capacity kW (kcal/h) 3,0 (2.580) Nominal thermal output kW (kcal/h) 11,1 (9.546) Reduced thermal power kW (kcal/h) 2,82 (2.425)
  • Page 21: Technical Specifications Rea 100

    AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 Technical Specifications REA 100 Nominal heat input kW (kcal/h) 10,24 (8.772) Reduced thermal capacity kW (kcal/h) 3,0 (2.580) Nominal thermal output kW (kcal/h) 9,48 (8.153) Reduced thermal power kW (kcal/h) 2,82 (2.425)
  • Page 22: Requirements Of The Place Of Installation

    AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 - Constant diameter cylinders with a smooth, shiny surface; - There should not be a lot of sawdust inside the packaging; - After grabbing a bunch of pellets and placing them into a container filled with water, good-quality pellets will sink and poor-quality ones will tend to float;...
  • Page 23: Spaces Around And Above The Appliance

    AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 Spaces around and above the appliance The figure below shows the minimum distances from walls or other not-easily-removable furniture, that need to be taken into consideration when positioning the appliance.
  • Page 24: The Flue And Connection To The Same

    AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 Fig. A The flue and connection to the same The flue is an essential element for the efficient operation of the appliance. The flue must have a minimum cross- sectional area as that indicated in the technical specifications of the appliance (80 mm).
  • Page 25: Chimney

    AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 - IT IS MANDATORY TO HAVE AN INITIAL VERTICAL SECTION OF AT LEAST 1.5 MT IN ORDER TO GUARANTEE CORRECT FLUE GAS DISCHARGE. - Every direction change must be carried out with a T-shaped fitting and inspection cap. The tubes must be air tight through special seals which resist up to 250°...
  • Page 26: Electrical Connection

    Do not pass electric cables in the immediate vicinity of the flue gas pipe, unless they are insulated with suitable materials. KLOVER srl declines all responsibility for injury to persons and animals or damage to objects due to failure to connect the appliance to earth or to comply with IEC specifications.
  • Page 27: Connection To The Room Thermostat Or A Room Temperature Sensor

    AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 Connection to the room thermostat or a room temperature sensor On the back of the appliance there are one or more terminal boards which are used to connect the room thermostat or room temperature sensor (see “Components of the appliance”)
  • Page 28: Description Of Components

    AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 DESCRIPTION OF COMPONENTS Remote control Display Key 1 – INCREASE Key 5 – ESC Key 2 – DECREASE Key 4 – SET Key 3 – ON/OFF The remote control must be fitted with 3 AAA 1.5 V batteries (mod.
  • Page 29: Support Panel

    AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 Support panel Led 6 – WIFI Led 4 – RECEPTION Led 5 – ALARM Led 3 – POWER STATUS Key 2 – POWER Led 2 – POWER STATUS...
  • Page 30: Display

    AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 The support panel allows you to control basic functions governing the operation of the appliance in the absence of the remote control. The following operations can be carried out:...
  • Page 31: The Menu

    AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 THE MENU Access the Menu by pressing key 4 (Set) on the remote control. The menu is divided into different items and levels, providing access to the programming and settings options of the appliance.
  • Page 32 AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 The image below shows the screen when the Timer is enabled: Enable field  Sub-menu 02 – 02 – Daily timer Allows you to enable, disable and set the daily timer functions.
  • Page 33 AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6  Sub-menu 02 – 03 – Weekly timer Allows you to enable, disable and set the timer weekly program functions. The weekly timer has four operating time slots can be set according to the following table (it is not essential to use all of...
  • Page 34 AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6  Sub-menu 02 – 04 – Weekend Timer Enables/disables/sets the programmable timer's weekend functions (valid on Saturday and Sunday). Switch on time (OFF tells the clock to ignore...
  • Page 35 AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 The table below shows the settings and their meanings: Menu Meaning Values that can be set * CARD BEEP Enables/disables the beep sound made by the power card ON –...
  • Page 36 AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 Indicates the status of the brazier cleaner. CLEANER (OFF = Contact OPEN = Brazier not aligned) (ON = Contact CLOSED = Brazier aligned) Indicates the status of the pellet level sensor in the tank.
  • Page 37: Initial Configurations

    3%. * Access by non-expert users can cause serious damage to the equipment, to things and the environment as well as personal injuries. Klover declines any responsibility for damages arising from inappropriate calibration. Menu 10 – Technical calibration Allows you to access all data reserved for the Technical Assistance Centre.
  • Page 38: Connection To The Wifi Network

    Connection to the WiFi network The appliance is fitted with a WiFi card that allows you to control it remotely via the “My Klover” Web App which you can download onto your smartphone, tablet or computer from the various App stores - Apple, Android, etc..
  • Page 39 AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 7. This will open the last configuration page (Search for available WiFi networks). Select the network to be used to connect the appliance to the Internet from the list and enter the password for the selected network. If the network is hidden, click on the item "Custom SSID"...
  • Page 40: Initial Start-Up

    App stores: Apple, Android, etc.. 11. Go back to the main page of the “My Klover” Web App and access your account by entering the details (email address and password) you entered during registration. You can now enter a new device by clicking on “Add stove” in the main menu.
  • Page 41: Ignition Cycle

    AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 - Fill the pellet tank; for the first ever ignition, to avoid wasting the time required for filling the entire screw feed channel (this should be done every time the appliance runs out of pellets), we recommend you follow the instructions in the “MENU 06 –...
  • Page 42: Switch-Off Cycle

    AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 Switch-off cycle Pressing key 3 (On/Off) on the remote control or key 1 (On/Off) on the support panel, will switch off the appliance. The display will show “SWITCHING OFF”. The pellet loading stops and the flue gas extractor speed increases to maximum and then switches off after the cooling of the appliance, displaying "OFF”.
  • Page 43: Modify Ducted Air Speed Set Values

    AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 POWER SET (Working power values between 1 and 5 can be set.) Modify ducted air speed Set values - To modify the speed of the ducted air fans (1 or 2 according to the model), select“SET DUCTING” by pressing key 5 (Esc).
  • Page 44: Problems, Alarms, Useful Advices

    AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 PROBLEMS, ALARMS, USEFUL ADVICES Useful info… Listed below is some important information regarding the appliance: - It is normal for the appliance to emit a smell of paint during its first few days of operation. We recommend ventilating the installation room during the initial start-up.
  • Page 45: Alarm Signals

    Every alarm causes the appliance to switch-off immediately. The alarm state is reached after the time set on Pr11 (set as default at 90”) and it can be reset by pressing button 3 for a while. In the event of a fault, contact the Klover Authorised technical assistance centre.
  • Page 46: Cleaning And Maintenance

    AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 CLEANING AND MAINTENANCE Precautions before cleaning Before carrying out any cleaning or maintenance operations, make sure that: - the appliance is off and has cooled down completely;...
  • Page 47 AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 Use the dedicated front heat exchanger cleaning hook to lift the rod and move it backwards and forwards to clean the air heat exchanger of combustion residues...
  • Page 48: Non-Routine Cleaning

    AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 Remove the ring covering the brazier and remove the combustion residues (figure Use a suitable ash vacuum device to remove any ash deposited in the brazier...
  • Page 49 AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 Remove the cast iron top, undoing the two screws shown in the picture (figure After having removed the two inspection plates in the picture (figure 9), clean the right and left flue gas conduits with a...
  • Page 50 AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 After having removed the front panel below (figure 13), remove the inspection vent, unscrewing the two screws (figure 14). After having removed the vent, vacuum the residues inside the compartment (figure 15).
  • Page 51: Cleaning The Vermiculite

    You must periodically check the seals because the latter guarantee the air- and water-tightness of the appliance and its good functioning; if they are worn or damaged you need to be replace them immediately by contacting a Klover Authorised technical assistance centre.
  • Page 52: Pcb Parameters

    The following parameters are already stored during the testing of the appliance directly in the factory; these parameters are the result of special tests using several types of pellets and must not be changed without the authorisation of Klover srl so as not to impair the operation of the appliance.
  • Page 53 AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 Parameters “FACTORY CALIBRATIONS” – Mod. A80 / CL90 (L09_161018) Database Parameter Menu level Description Display Measurement Value field Pr01 M10 – 05 – 01 Ignition cycle maximum time IGN.
  • Page 54: Parameter Tables For Aura 80 Multi-Air / Class 90 Multi-Air

    AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 Parameter tables for AURA 80 MULTI-AIR / CLASS 90 MULTI-AIR Parameters “CLEANER CALIBRATIONS” - Mod. AC80 / CLC90 (L09_161018) Database Parameter Menu level Description Display Measurement...
  • Page 55 AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 Pr05 M10 – 05 – 05 Screw feed gear motor ON time in stabilisation phase SC.F. STABILISE Seconds 0.1 – 8.0 Pr06 M10 – 05 – 06 Screw feed gear motor ON time in power 1 work phase SC.F.
  • Page 56: Parameter Tables For Aura 120

    AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 Parameter tables for AURA 120 Parameters “CLEANER CALIBRATIONS” - Mod. A120 (L09_161018) Database Parameter Menu level Description Display Measurement Value field Pr51 M10 – 01 – 01...
  • Page 57 AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 Pr05 M10 – 05 – 05 Screw feed gear motor ON time in stabilisation phase SC.F. STABILISE Seconds 0.1 – 8.0 Pr06 M10 – 05 – 06 Screw feed gear motor ON time in power 1 work phase SC.F.
  • Page 58: Parameter Tables For Aura 120 Multi-Air

    AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 Parameter tables for AURA 120 MULTI-AIR Parameters “CLEANER CALIBRATIONS” - Mod. AC120 (L09_161018) Database Parameter Menu level Description Display Measurement Value field Pr51 M10 – 01 – 01...
  • Page 59 AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 Pr05 M10 – 05 – 05 Screw feed gear motor ON time in stabilisation phase SC.F. STABILISE Seconds 0.1 – 8.0 Pr06 M10 – 05 – 06 Screw feed gear motor ON time in power 1 work phase SC.F.
  • Page 60: Parameter Tables For Rea 100

    AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 Parameter tables for REA 100 Parameters “CLEANER CALIBRATIONS” - Mod. R100 (L09_161018) Database Parameter Menu level Description Display Measurement Value field Pr51 M10 – 01 – 01...
  • Page 61 AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 Pr05 M10 – 05 – 05 Screw feed gear motor ON time in stabilisation phase SC.F. STABILISE Seconds 0.1 – 8.0 Pr06 M10 – 05 – 06 Screw feed gear motor ON time in power 1 work phase SC.F.
  • Page 62: Wiring Diagram

    AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6 WIRING DIAGRAM...
  • Page 63: Standard Warranty Conditions

    The Klover Warranty will remain in effect for a period of 2 years from the date of purchase, if proven by a delivery note or other proof of purchase (e.g. receipt), stating the name of the seller, the product that was bought, and the date of purchase.
  • Page 64 Klover Products must undergo functional testing before any related masonry works are carried out (for example before tiling, installation of pilasters, or painting of the walls). Klover Srl is not liable for any costs incurred as a result of removal and/or reconstruction of related installations, or for any other ancillary intervention even if it is the result of works to replace defective parts.
  • Page 65 AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6...
  • Page 66 AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6...
  • Page 67 AURA 80, CLASS 90, AURA 120, REA 100 PELLET-BURNING STOVE EN - Rev. 1.6...
  • Page 68 Cod. CS.IST.A80-EN KLOVER Srl Via A. Volta, 8 37047 San Bonifacio (VR) VAT No. 02324280235 www.klover.it...

This manual is also suitable for:

Aura 120Class 90Rea 100

Table of Contents