GAS CONTROL VALVE
For Natural Gas
• Inlet screen helps protect from debris.
• Tamper resistant screws.
• Conveniently located ON/OFF switch.
• Inlet and Outlet pressure taps.
• Adjustable gas regulator.
Note: ON/OFF switch must be in the ON position to perform ohm/continuity tests. ON/OFF switch replaced
the gas cock on this new valve design.
GAS PRESSURE SPECIFICATIONS:
MODELS
Maximum Gas Supply Pressure
Minimum Gas Supply Pressure
† Pilot Burner Pressure
† Main Burner/ Manifold Pressure
†. Gas pressures given have a tolerance of ± 0.3" W.C.
10
SBD 71120-100390
Servicing should only be performed by a Qualified Service Technician
NATURAL
13.8" W.C.
4.5" W.C.
3.5" W.C.
3.5" W.C.
For Propane (LP)
PROPANE
SBD 71120-100390
13.8" W.C.
11.0" W.C.
10.0" W.C.
10.0" W.C.