Device
Setting
a) Even when THROUGH MODE is set to ON, always connect a
reference signal and frequency locking signal.
b) Also performs HDR/SDR output signal switching.
c) You can select the channel A input signal.
d) When a signal from a Sony system camera is input, set the same
setting that is configured on the camera.
e) Adjustment using this page is not required if settings on the <HDR/
SDR SETUP> (previous) page are configured correctly. Set the
master black level on this page if a signal is input from other than
a Sony system camera or if the signal master black level is
undefined.
f) When INPUT LEVEL CHECK is set to ON, the master black level
added to the output signal becomes zero, so you can make an
adjustment so that the output signal is 0% for the equivalent of an
input signal with the iris fully closed.
Menu/Page
SETUP/<OUTPUT: SDR
d)
KNEE>
(S05)
SETUP/<INPUT&OUTPUT:
d)
SDR GAMMA>
(S06)
Item
CHANNEL A
SDR KNEE
SDR KNEE SATURATION ON/OFF
CHANNEL B
SDR KNEE
SDR KNEE SATURATION ON/OFF
CHANNEL A
INPUT&OUTPUT SDR
GAMMA
OUTPUT SDR GAMMA
CHANNEL B
INPUT&OUTPUT SDR
GAMMA
OUTPUT SDR GAMMA
10
Set value
Sets the SDR output
signal knee of channel A
ON/OFF
POINT
SLOPE
Sets the SDR output
signal knee of channel B
ON/OFF
POINT
SLOPE
Sets the SDR output
gamma of channel A
TABLE
SDR signal gamma table
and number
ON
Turns the output SDR
signal gamma on
LEVEL
Adjusts the output SDR
signal gamma
COARSE
Output SDR signal
gamma step
Sets the SDR output
gamma of channel B
TABLE
SDR signal gamma table
and number
ON
Turns the output SDR
signal gamma on
LEVEL
Adjusts the output SDR
signal gamma
COARSE
Output SDR signal
gamma step