Wireless Smart Gluco-Monitoring System (BG5) OWNER’S MANUAL Wireless Smart Gluco-Monitoring System (BG5) Table of Contents INTRODUCTIN OWNER’S MANUAL PACKAGE CONTENTS SETUP REQUIREMENTS INTENDED USE HOW THE TEST WORKS? IMPORTANT SAFETY INSTRUCTIONS IMPORTANT TESTING INFORMATION INFORMATION ABOUT ALTERNATIVE SITE TESTING (AST)
Page 2
Due to its compact size and easy operation, you IMPORTANT INFORMATION ABOUT CONTROL can use the iHealth Wireless Smart Gluco-Monitoring SOLUTION TESTS System (BG5) to easily monitor your blood glucose levels on METER MEMORY your own, anywhere, any time. Offline measurement mode:(not using iOS device)
The iOS version of these devices should be V5.0 or higher. INTENDED USE • Travel Case • USB Charging • Control Solution* The iHealth Wireless Smart Gluco-Monitoring System (BG5) Cable should be used for: • Quantitative measurement of glucose in fresh capillary whole blood samples drawn from the fingertip, palm, forearm, upper arm, calf or thigh •...
• Do not use in a manner not specified by the manufacturer. Please carefully read the following information before using the iHealth Wireless Smart Gluco-Monitoring System (BG5). IMPORTANT TESTING INFORMATION Always keep these instructions in a safe place for reference.
fingertips. The Wireless Smart Gluco-Monitoring System AST is suitable in the following instances: (BG5) allows you to test on the palm, forearm, upper arm, • In a pre-meal or fasting state (two hours or more after the calf, or thigh with equivalent results to fingertip testing.
Located in the side of the meter, It is used to turn on the meter and view past test results. NOTE: Only use iHealth Blood Glucose Test Strip with the iHealth Wireless Smart Gluco-Monitoring System (BG5). Other test strips may produce inaccurate results.
Obtaining a Blood Sample 1. Download the Free iHealth App The detailed procedure reference iHealth Lancing Device. Prior to first use, download and install the free iHealth App from the App Store. Use keyword search terms “iHealth,” Apply Your Blood Sample “BG5”...
Obtaining a Blood Sample Note: Please consult a healthcare professional The detailed procedure reference for interpretation of blood glucose measurements. iHealth Lancing Device. For additional information, please visit: www.ihealthlabs.com...
Material needed: will not be treated as a control solution test. • iHealth Wireless Smart Gluco-Monitoring System (BG5) • iHealth AGS-1000I Blood Glucose Test Strip Step 4: Apply Control Solution •...
If you continue to get Control Solution test results that fall mg/dL outside of the range printed on the vial, the meter may not be working properly. Discontinue use and call iHealth Labs Note: When the meter memory is full, the oldest test result Customer Service at +1-855-816-7705 for assistance.
• Take your Wireless Smart Glucose Meter with you to the lab. meter will automatically shut off. While at the Lab REFERENCE VALUE OF THE IHEALTH WIRELESS SMART Make sure that samples for both tests are taken and tested GLUCOSE METER within 15 minutes of each other.
Page 12
4. Take off the glove and the protective cover. active ingredient, have been shown to be safe for use with Note: the BG5 Blood Glucose meter and lancing device. 1. Each disinfection step requires a pre-cleaning step. You can purchase this product according to the following 2.
3. Measuring method: Amperometric technology using used with iHealth test strips (AGS-1000I). glucose oxidase • The iHealth Wireless Smart Glucose Meter can be used up 4. Result range: 20 mg/dL~600 mg/dL (1,1 mmol/L ~33,3 to an altitude of 3276 meters(10744feet).
Error Message We recommend periodic comparison of the iHealth Wireless Smart Gluco-Monitoring System to another monitoring system known to be well maintained and monitored by a MESSAGE WHAT IT MEANS ACTION healthcare provider. The meter’s battery Please charge the battery.
4.System is not performing 4. Bring the system to a due to the environment room-temperature iHealth is a trademark of iHealth Lab Inc. being above or below environment and wait room temperature. approximately 30 minutes “Made for iPod” “Made for iPad”and “Made for iPhone”...
Changes or modifications not expressly approved by iHealth Lab Inc. would void the user’s authority to operate the product. Note: This product has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
Need help?
Do you have a question about the BG5 and is the answer not in the manual?