Setting Of Dip Switches And Rsw Switches - Hitachi RWM-2.5NE Instruction Manual

Yutaki s series rwm-(2.0-10.0)ne
Hide thumbs Also See for RWM-2.5NE:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 9
ELECTRICAL AND CONTROL SETTINGS
Mark
Part name
32(C)
Common line
33(L)
3-way valve for DHW tank
34(N)
N common
Output 1 (3-way valve for swimming
35(L)
pool) (*)
36(L)
Output 2 (Water pump 3 (WP3)) (*)
37
Output 3 (Auxiliary boiler or electric
heater) (*)
38
39
Output 4 (Solar) (*)
40
?
N O T E
(*): Inputs and outputs explained in the table are the factory-set options. By means of the unit controller, some other inputs and outputs functions can
be configured and used. Please, refer to the Service Manual for detailed information.

5.6 SETTING OF DIP SWITCHES AND RSW SWITCHES

5.6.1 Location of DIP switches and rotary switches
16
PMML0336B rev.1 - 03/2016
Common terminal for the 3-way valve for DHW tank.
The air to water heat pump can be used to heat DHW. This output will be on when DHW is
activated.
Neutral terminal common for 3-way valve of DHW tank and outputs 1 and 2.
The air to water heat pump can be use to heat swimming pool. This output will be ON when
swimming pool is activated.
When there is a hydraulic separator or buffer tank, additional water pump (WP3) is needed.
The boiler can be used to alternate with the heat pump when the heat pump cannot achieve the
required temperature by itself.
A water electric heater (as accessory) can be used to provide the additional heating required on
the coldest days of the year.
Output for solar combination with Domestic Hot Water Tank.