Specifications; Unit Specifications; Specifications 2-1. Unit Specifications - Sanyo SAP-DMRV93GJ Technical & Service Manual

Dc inverter multi-system air conditioner
Table of Contents

Advertisement

2. SPECIFICATIONS

2-1. Unit Specifications

Indoor Unit
SAP – DMRV93GJ
Type
Power Source
Voltage rating
Performance
Capacity
Air circulation (Hi / Me / Lo)
Moisture removal (High)
External
static pressure
Electrical Rating
Available voltage range
Running amperes
Power input
Features
Controls / Temperature control
Control unit
Timer
Fan speeds
Airflow direction (Indoor)
Air filter
Operation sound
Refrigerant tubing connections
Refrigerant
tube diameter
Refrigerant
Refrigerant tube kit
Dimensions & Weight
Unit dimensions
Package dimensions
Weight
Shipping volume
kW
m
3
Liters/h
(Low)
Pa
(High)
Pa
Horizontal
Vertical
Hi / Me / Lo
dB-A
Narrow tube
mm (in.)
Wide tube
mm (in.)
Height
mm
Width
mm
Depth
mm
Height
mm
Width
mm
Depth
mm
Net
kg
Shipping
kg
m
Concealed duct type indoor unit
220–240V ~ 50Hz
230 V
Cooling
2.8
( 0.7 - 3.2 )
850 / 760 / 700
/h
1.6
0 to 19.6
19.6 to 73.5
19.6 to 73.5
Cooling
V
198 ~ 264
A
0.41
W
95
Microprocessor / I.C. thermostat
Wireless remote control unit
ON/OFF 24 hours & Daily program,1-hour OFF
41 / 39 / 37
g
3
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
2
220V ~ 60Hz
2.8
850 / 760 / 700
0 to 19.6
0 to 19.6
19.6 to 73.5
3 and Auto
Field supply
41 / 39 / 37
Flare type
6.35(1/4)
9.52(3/8)
R410A
Optional
260
958
479
374
1,039
586
19
25
0.23
220 V
Cooling
( 0.7 - 3.2 )
1.6
0 to 19.6
19.6 to 73.5
Cooling
198 ~ 242
0.40
90

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sap-dmrv123gjSap-dmrv183gjSap-dmrv243gj

Table of Contents