(3) Connecting indoor unit type 183 at D (Length of tube: less than 17 m)
(4) Connecting indoor unit type 243 at D

7-2. Embedding the Tubing and Wiring

Before beginning embedding installation work, consult
fully with agencies or offices related to the building's
foundation, construction, electricity, and water.
Wait to make connections to the embedded portion.
Each connection step is described later in this
manual.
Securely cover the end of the embedded tubing to
prevent intrusion of dirt or moisture.
If an embedded tube is to be left for a long time, fill the
tube with nitrogen and seal both ends securely.
If a tube is left open for an extended time, moisture in the
air inside the tubing may condense into water droplets,
and lead to water contamination of the refrigerant circuit.
In order to prevent insulation breakdown and ground
faults, do not allow wiring ends to come in contact with
rainwater, or be subjected to condensation or dew.
Apply sufficient thermal insulation to the refrigerant
tubing and drain pipes.
Outdoor unit
A
φ9.52
B
φ9.52
C
φ9.52
D
φ12.7
Flare φ12.7
Union φ9.52
(φ12.7 → φ9.52) Supplied Reducer
Outdoor unit
A
φ9.52
B
φ9.52
C
φ9.52
D
φ12.7
φ6.35
φ9.52
φ6.35
φ9.52
φ6.35
φ9.52
φ6.35
φ9.52
Fig. 5c
φ6.35
φ9.52
φ6.35
φ9.52
φ6.35
φ9.52
φ6.35
φ12.7
Fig. 5d
21
Indoor unit
(93 123 types)
(93 123 types)
(93 123 types)
(183 type)
Indoor unit
(93 123 types)
(93 123 types)
(93 123 types)
(243 type)