Daikin DCG036XXX1DXXX Technical Manual page 43

Dcg commercial gas units 3 - 6 tons with r410a
Table of Contents

Advertisement

WIRING DIAGRAMS
L1
L1
SUPPLY VOLTAGE
SUPPLY VOLTAGE
C
C
T1
T1
T1
T1
BC
BC
EM
EM
NOTE 3
NOTE 3
FS
FS
F
H C
H C
D1
D1
4
4
5
5
3
3
IIC
6
6
8
8
9
9
7
7
10
10
12
12
11
11
R
R
W1
S1
S2
W2
TO THERMOSTAT
TERMINAL BLOCK
INSTALLER/SERVICEMAN
INSTALLER/SERVICEMAN
STATUS LIGHT
STATUS LIGHT
EQUIP. STATUS
EQUIP. STATUS
ON
ON
NORMAL OPERATION
NORMAL OPERATION
OFF
OFF
INTERNAL CONTROL
INTERNAL CONTROL
IGNITION FAILURE
IGNITION FAILURE
1 BLINK
1 BLINK
OPEN AUX. LIMIT
OPEN AUX. LIMIT
PRESSURE SWITCH
PRESSURE SWITCH
2 BLINKS
2 BLINKS
3 BLINKS
3 BLINKS
WITHOUT INDUCER ON
WITHOUT INDUCER ON
4 BLINKS
4 BLINKS
OPEN LIMIT SWITCH
OPEN LIMIT SWITCH
5 BLINKS
5 BLINKS
FALSE FLAME SENSED
FALSE FLAME SENSED
6 BLINKS
6 BLINKS
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
WARNING
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
208-240/3/60
208-240/3/60
C
C
T2
T2
T2
T2
T3
T3
T3
T3
C
C
FC
FC
CM
CM
BC
BC
BC
BC
1
1
VMR
VMR
1
1
3
3
TR
TR
IGN
IGN
BC
BC
FS
FS
VMR
VMR
LS
LS
ALS
ALS
RS
RS
GV
GV
PS
PS
C
C
LPS
LPS
HPS
HPS
G
G
Y1
Y1
Y2
C
C
NOTE 2
CHECK
CHECK
NO POWER OR
NO POWER OR
GAS FLOW
GAS FLOW
GAS PRESSURE
GAS PRESSURE
OPEN ROLLOUT
OPEN ROLLOUT
GAS VALVE
GAS VALVE
SWITCH
SWITCH
FLAME SENSOR
FLAME SENSOR
FLAME ROLLOUT
FLAME ROLLOUT
BAD SWITCH
BAD SWITCH
SWITCH
SWITCH
AUX. LIMIT OPEN
AUX. LIMIT OPEN
CHECK
CHECK
PRESSURE SWITCH
PRESSURE SWITCH
OPEN
OPEN
CHECK
CHECK
PRESSURE SWITCH
PRESSURE SWITCH
MAIN LIMIT OPEN
MAIN LIMIT OPEN
BAD SWITCH
BAD SWITCH
COMPRESSOR
COMPRESSOR
3 MIN. COMP.
3 MIN. COMP.
OUTPUT DELAY
OUTPUT DELAY
COMPONENT LEGEND
COMPONENT LEGEND
L2
L2
L3
L3
AUXILIARY LIMIT SWITCH
AUXILIARY LIMIT SWITCH
ALS
ALS
BC
BC
BLOWER CONTACTOR
BLOWER CONTACTOR
COMP
COMP
COMPRESSOR
COMPRESSOR
CM
CM
CONDENSER MOTOR
CONDENSER MOTOR
C
C
CONTACTOR
CONTACTOR
EM
EM
EVAPORATOR MOTOR
EVAPORATOR MOTOR
F
F
FUSE
FUSE
FC
FC
FAN CAPACITOR
FAN CAPACITOR
FS
FS
FLAME SENSOR
FLAME SENSOR
GND
GND
EQUIPMENT GROUND
EQUIPMENT GROUND
GV
GV
GAS VALVE
GAS VALVE
HPS
HPS
HIGH PRESSURE SWITCH
HIGH PRESSURE SWITCH
IBR
IBR
INDOOR BLOWER RELAY
INDOOR BLOWER RELAY
IIC
IIC
INTEGRATED IGNITION CONTROL
INTEGRATED IGNITION CONTROL
VM
VM
IGN
IGN
IGNITOR
IGNITOR
LPS
LPS
LOW PRESSURE SWITCH
LOW PRESSURE SWITCH
LS
LS
LIMIT SWITCH
LIMIT SWITCH
PLF
PLF
FEMALE PLUG/CONNECTOR
FEMALE PLUG/CONNECTOR
NOTE 3
NOTE 3
PS
PS
PRESSURE SWITCH
PRESSURE SWITCH
RS
RS
ROLLOUT SWITCH
ROLLOUT SWITCH
IIC
IIC
TB1
TB1
TERMINAL BLOCK (24V SIGNAL)
TERMINAL BLOCK (24V SIGNAL)
TR
TR
TRANSFORMER
TRANSFORMER
VM
VM
VENT MOTOR
VENT MOTOR
VMR
VMR
VENT MOTOR RELAY
VENT MOTOR RELAY
NOTES
NOTES
1. REPLACEMENT WIRE MUST BE THE SAME
1. REPLACEMENT WIRE MUST BE THE SAME
SIZE AND TYPE OF INSULATION AS ORIGINAL.
SIZE AND TYPE OF INSULATION AS ORIGINAL.
(USE COPPER CONDUCTOR ONLY).
(USE COPPER CONDUCTOR ONLY).
2. ACCESSORY ECONOMIZER PLUG ADJACENT
2. ACCESSORY ECONOMIZER PLUG ADJACENT
TO BLOWER HOUSING IN RETURN AIR
TO BLOWER HOUSING IN RETURN AIR
COMPARTMENT. REMOVE MALE PLUG AND
COMPARTMENT. REMOVE MALE PLUG AND
ATTACH FEMALE PLUG TO THE ECONOMIZER
ATTACH FEMALE PLUG TO THE ECONOMIZER
ACCESSORY.
ACCESSORY.
3. L1 AND L2 ON IIC CONTROL IS 24V INPUT.
3. L1 AND L2 ON IIC CONTROL IS 24V INPUT.
9 8 7
4. USE COPPER CONDUCTORS ONLY.
4. USE COPPER CONDUCTORS ONLY.
USE NEC CLASS 2 WIRE.
USE NEC CLASS 2 WIRE.
6
6
5
5
4
4
5. FOR 208 VOLT TRANSFORMER OPERATION,
5. FOR 208 VOLT TRANSFORMER OPERATION,
PLF
3
3
2
2
1
1
MOVE BLACK WIRE FROM TERMINAL 3 TO
MOVE BLACK WIRE FROM TERMINAL 3 TO
TERMINAL 2 ON TRANSFORMER.
TERMINAL 2 ON TRANSFORMER.
SEE UNIT RATING PLATE FOR TYPE AND SIZE
OF OVER CURRENT PROTECTION
-
-
208-240/3/60 0140L02901-A
DCG0360453BXXXA*
FACTORY WIRING
FACTORY WIRING
LINE VOLTAGE
LINE VOLTAGE
LOW VOLTAGE
LOW VOLTAGE
OPTIONAL
OPTIONAL
HIGH VOLTAGE
HIGH VOLTAGE
FIELD WIRING
FIELD WIRING
HIGH VOLTAGE
HIGH VOLTAGE
LOW VOLTAGE
LOW VOLTAGE
WIRE CODE
WIRE CODE
BK BLACK
BK BLACK
BL BLUE
BL BLUE
BR BROWN
BR BROWN
GR GREEN
GR GREEN
OR ORANGE
OR ORANGE
PK PINK
PK PINK
PU PURPLE
PU PURPLE
RD RED
RD RED
WH WHITE
WH WHITE
YL YELLOW
YL YELLOW
BL/PK BLUE WITH PINK STRIP
BL/PK BLUE WITH PINK STRIP
YL/PK YELLOW WITH PINK STRIP
YL/PK YELLOW WITH PINK STRIP
THERMOSTAT
THERMOSTAT
FIELD WIRING
FIELD WIRING
NO ECONOMIZER
NO ECONOMIZER
W
W
G
G
R
R
Y1
Y1
Y2
C
C
TB1
TB1
WITH ECONOMIZER OPTION
WITH ECONOMIZER OPTION
W
W
G
G
R
R
Y1
Y1
Y2
C
C
TB1
TB1
2 STA GE COOLING
2 STA GE COOLING
W
W
G
G
R
R
Y1
Y1
Y2
C
C
TB1
TB1
WH
WH
W
W
GR
GR
G
G
RD
RD
R
R
YL
Y
BL
BL
C
C
STAT
STAT
WH
WH
W
W
GR
GR
G
G
RD
RD
R
R
YL
YL
Y
Y
BL
BL
C
C
STAT
STAT
WH
WH
W
W
GR
GR
G
G
RD
RD
R
R
YL
YL
Y1
Y1
PK
PK
Y2
Y2
BL
BL
C
C
STAT
STAT
43

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents