Product Identification - Daikin DCG036XXX1DXXX Technical Manual

Dcg commercial gas units 3 - 6 tons with r410a
Table of Contents

Advertisement

PRODUCT IDENTIFICATION

The model number is used for positive identification of component parts used in manufacturing. Please use this number
when requesting service or parts information.
Brand
D
Daikin
Configuration
C
Commercial Package
Application
C
Cooling
G
Gas Heat
H
Heat Pump
Nominal Gross Cooling Capacity
036
3 Tons
102
8½ Tons
048
4 Tons
120
10 T ons
060
5 Tons
150
12½ Tons
072
6 Tons
180
15 T ons
090
7½ Tons
240
20 T ons
Nominal Heating Capacity
DCG
DCC/DCH(Factory-Installed Electric Heat)
045
45,000 BTU/h
XXX
090
90,000 BTU/h
010
115
115,000 BTU/h
015
140
140,000 BTU/h
016
210
210,000 BTU/h
018
350
350,000 BTU/h
020
400
400,000 BTU/h
025
See product specifications for heat size(s) available for each capacity.
Voltage
1
208V 1-Phase
3
208v 3-Phase
Supply Fan/Drive Type/Motors
B
Belt Drive
D
Direct Drive
Factory-Installed Options
X
No Options
A
Downflow Economizer
H
Disconnect Switch (non-fused)
J
Downflow Economizer ; Disconnect Switch (non-fused)
Note: Not all options available for all products.
Factory-Installed Options
Stainless-Steel Heat Exchanger (DCG units only): A tubular heat exchanger made of 409-type
stainless steel is installed in the unit.
Low-Ambient Kit: Allows for cooling operation at lower outdoor temperatures. On the 3-6 ton units, cooling operation is extended for 60ºF
ambient temperature to 35ºF outside air temperature. On 7½ to 20 ton units, cooling operation is extended from 35ºF ambient temperature to 0ºF
outside air temperature.
Economizers (Downflow): Based on air conditions, can provide outside air to cool the space.
Electric Heat Kits (DCC and DCH units only): Available in all voltage options.
Non-powered Convenience Outlet: A 120V,15A,GFCI outlet makes it easier for technicians to service the unit once an electrician runs power to the outlet.
Powered Convenience Outlet: A 120V, 15A, GFCI outlet powered with a transformer built into the unit; for use when unit is not running.
Disconnect Switch (non-fused): A disconnect switch is installed in the unit and factory wiring will be complete from the switch to the unit. Please note
that for air conditioning (DCC units) and heat pump models (DCH units), the appropriate electric heat kit must be ordered to be factory-installed along
with the disconnect switch (non-fused) when it is ordered. Please note that for models with a powered convenience outlet option and a disconnect switch
(non-fused) option, the power to the powered convenience outlet will be shut off when the disconnect switch (non-fused) is in the off position.
Return Air and/or Supply Air Smoke Detectors: Return air and/or supply air smoke detectors are installed in the unit.
D
C
C
240
1
2
3
4, 5, 6
7, 8, 9
No Heat
10 kW
030
30 kW
15 kW
031
30 kW
15 kW
045
45 kW
18 kW
046
46 kW
20 kW
060
60 kW
25 kW
4
460V 3-Phase
7
575V 3-Phaze
V
2-Speed Belt Drive
60
3
B
*
*
10
11
12
13
*
A
*
14
15
16
Revision Levels
Major & Minor
Factory-Installed Options
X No Options
A Non-powered convenience outlet
B Powered convenience outlet
C Low Ambient Kit
D Return air smoke detector
E Supply air smoke detector
F Non-powered convenience outlet;
Low Ambient Kit
G Non-powered convenience outlet;
Return air smoke detector
H Non-powered convenience outlet;
Supply air smoke detector
J
Non-powered convenience outlet;
Return & Supply air smoke detectors
K Non-powered convenience outlet;
Low-ambient kit; Supply air smoke detector
L
Non-powered convenience outlet;
Low Ambient Kit;
Return & Supply air smoke detectors
M Powered convenience outlet;
Low Ambient Kit
N Powered convenience outlet;
Return air smoke detector
O Powered convenience outlet;
Return & Supply air smoke detectors
P Powered convenience outlet;
Supply air smoke detector
Q Powered convenience outlet;
Low Ambient Kit;
Return air smoke detector
R Powered convenience outlet;
Low Ambient Kit; Supply air smoke detector
T Powered convenience outlet;
Low Ambient Kit;
Return & Supply air smoke detectors
U Non-powered convenience outlet;
Low-ambient kit; Return air smoke detector
V Low Ambient Kit;
Return air smoke detector
W Low Ambient Kit;
Return & Supply air smoke detectors
Y Low Ambient Kit;
Return & Supply air smoke detectors
Z Return & Supply air smoke detectors
Factory-Installed Options
X Standard Aluminized Heat Exchanger
S Stainless Steel Heat Exchanger
3