12:10 HP HIGH PRESSURE CHECK COOLING SYSTEM AND FILTERS
The error is activated if the input HP HIGH PRESSURE (high pressure switch, P1) has tripped.
The errror can be trigged if there is no cooling water to machine or if the airflow is obstructed, by lint, overload, etc.
The error can be restored with the knob when the pressure is restored and the ongoing program will continue.
Recommended actions:
1. Check the harness, connectors and functions by reading the electrical schematic and by using the SHOW INPUTS
menu when the machine is in service mode.
2. Check cooling water supply.
3. Check airflow and clean filters.
12:11 DRYING ERROR WITH RMC PROGRAM
The error code is shown if the analog input RMC does not register the STOP VALUE FOR RMC PROGRAM reached
within the maximum drying time (normally 90 minutes). When the error is trigged the machine will automatically go to
the cooling module before the program ends.
The program is ended and the error code is reset by opening the door.
If the clothes are still wet after maximum drying time and the dryer is not overloaded, check that the heating system
is working correct by using the ACTIVATE OUTPUTS menu when the machine is in service mode.
Note!
Make sure that the fan is active before turning on the heat.
If the clothes are dry, check the RMC system and harness, connectors and functions by reading the electrical sche-
matic and by using the SHOW INPUTS menu when the machine is in service mode.
• RMC value no load = 0%
• RMC value 100K Ohm between lifter and drum = ~24% (Putting your hand over the lifter onto the drum will result
in approximately 20% RMC value)
• RMC value system short circuit = 50%
12:12 DRYING ERROR WITH AUTOSTOP PROGRAM
The error code is shown if the analog input OULET AIR TEMP (NTC) does not register the STOP VALUE FOR AU-
TOSTOP PROGRAM reached within the maximum drying time (normally 90 minutes).
When the error is trigged the machine will automatically go to the cooling module before the program ends.
The program is ended and the error code is reset by opening the door.
If the clothes are still wet after maximum drying time and the dryer is not overloaded, check that the heating system
is working correct by using the ACTIVATE OUTPUTS menu when the machine is in service mode.
Note!
Make sure that the fan is active before turning on the heat.
If the clothes are dry, check the outlet air sensor and harness, connectors and functions by reading the electrical
schematic and by using the SHOW INPUTS menu when the machine is in service mode.
12:13 DRYING ERROR WITH TIME PROGRAM
The error code is shown if a time program has continued longer than the maximum drying time (normally 90 minutes)
without the door has been opened.
When the error is trigged the machine will automatically go to the cooling module before the program ends.
The program is ended and the error code is reset by opening the door.