Alarm Conditions - Hotpoint MSZ802DF Service Information

Side-by-side fridge freezers
Hide thumbs Also See for MSZ802DF:
Table of Contents

Advertisement

Indesit
Company

ALARM CONDITIONS

Control Panel Interface (mounted above dispenser assembly)
Example above shows the
Check fridge Air Baffle (Damper) / Connections.
TEMPERATURE DISPLAY
Freezer
C
- -
-9°C or warmer
CF
ICON DISPLAY
Cubed Ice
* If the food has thawed out, it MUST NOT be refrozen.
To turn the acoustic buzzer off during an alarm condition, press the reset button 'D' once.
To restore the alarm condition back to normal operation proceed as follows:
1. Press the main RESET button (D).
2. Remove from the mains power.
3. Reconnect the main power.
Service Manual UK
ALARM
'd' flashing in the fridge temperature display.
Fridge
Check freezer sensor / connections.
Freezer too warm usually shown when turned on for the
first time *.
Temperature reached during a power cut *.
Communication alarm between the control and display
module. Check connections to both modules. Note: The
appliance will run on default settings until fault is rectified.
C
Check fridge sensor / connections.
d
Check fridge air baffle (damper) / connections.
Crushed Ice
Check fill valve ice maker solenoid and connections.
ALARM CONDITION
ALARM CONDITION
15 of 37
English

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msz806dfMsz803dfMsz801df

Table of Contents