Dahua ITC114-PH1B User Manual

Dahua ITC114-PH1B User Manual

2nd generation video parking detector

Advertisement

Quick Links

2nd Generation Video Parking Detector User's Manual
Version 1.0.0
For ITC114-PH1B-F3, ITC114-PH1B-F6,
ITC314-PH1B-F2, ITC314-PH1B-F3

Advertisement

Table of Contents
loading

Summary of Contents for Dahua ITC114-PH1B

  • Page 1 2nd Generation Video Parking Detector User’s Manual Version 1.0.0 For ITC114-PH1B-F3, ITC114-PH1B-F6, ITC314-PH1B-F2, ITC314-PH1B-F3...
  • Page 2 Important Safeguards and Warnings Please read the following safeguards and warnings carefully before using the product in order to avoid damages and losses. Note:  Do not expose the device to lampblack, steam or dust. Otherwise it may cause fire or electric shock.
  • Page 3: Table Of Contents

    Table of Contents Important Safeguards and Warnings ................... ii General Introduction ...................... 1 Product Overview ....................1 Features ......................1 Framework........................3 Product Appearance ..................3 Device Dimensions ................... 3 Device Structure ....................4 Device Wiring ....................5 Installation ........................7 Quick Configuration Tool ....................
  • Page 4: General Introduction

    Parking status indicator supports remote control, network connection supports indicator color setup. Multi-parking Detection  ITC114-PH1B series parking detector supports detection of 1~2 parking at the same time.  ITC314-PH1B series parking detector supports detection of 1~3 parking at the same time. Intelligent Detection...
  • Page 5 Cascading Network Support network cascading, recommend device cascading <20 units, cascading network length <100m. Width Voltage Standard voltage 12V, adaptable to DC 8V~DC 26V non-standard voltage. 360-degree Rotation Lens support 360-degree rotation, angle of pitch supports 90-degree adjustment. Network Same-Link Connection Network same-link connection, built-in network bypass function.
  • Page 6: Framework

    2 Framework 2.1 Product Appearance Figure 2- 1 Figure 2- 2 2.2 Device Dimensions Device unit height is 118mm, diameter is 105mm.
  • Page 7: Device Structure

    Figure 2- 3 Figure 2- 4 2.3 Device Structure...
  • Page 8: Device Wiring

    ‘ Figure 2- 5 Component Lens Dome enclosure. Triaxial rotation module. Indicator 2.4 Device Wiring Cables of the parking detector are shown in Figure 2- 6.
  • Page 9 Figure 2- 6 Note Network port. Network port. Power port. 1:Connect to +12V power. 2:GND Alarm port. 1:Alarm input Red:ALARM_IN   Black:ALARM_GND 2:Alarm output Green:ALARM_OUT  Blue:ALARM_COM  RS485 port. Yellow:RS485A   Orange:RS485B...
  • Page 10: Installation

    3 Installation Note: The installation surface must be able to bear at least 3X of total weight of bracket and detector. Step 1. At device installation position, use electric drill to dig one hole with diameter of 35mm on the bridge Note: Screw hole diameter is 33mm.
  • Page 11 Figure 3- 3 Step 4. Refer to Ch 2.4 for wiring. Step 5. Adjust camera viewing angle according to actual condition, and then fix the screw. Step 6. Put back cover.
  • Page 12: Quick Configuration Tool

    4 Quick Configuration Tool 4.1 Overview Quick configuration tool can search current IP address, modify IP address. At the same time, you can use it to upgrade the device. Please note the tool only applies to the IP addresses in the same segment. 4.2 Operation Double click the “ConfigTools.exe”icon, you can see an interface is shown as in Figure 4- 1...
  • Page 13 Figure 4- 2 Select the “Open Device Web” item; you can go to the corresponding web login interface. See Figure 4- 3 Figure 4- 3 If you want to modify the device IP address without logging in the device web interface, you can go to the configuration tool main interface to set.
  • Page 14 Figure 4- 4 Figure 4- 5 After you logged in, the configuration tool main interface is shown as below. See Figure 4- 5 For detailed information and operation instruction of the quick configuration tool, please refer to the Quick Configuration Tool User’s Manual included in the resources CD.
  • Page 15: Web Operation

    5 Web Operation 5.1 Introduction Device supports access and manage device via WEB from PC.  By configuring device network, camera, intelligent business, a user can monitor and send HD image.  Search log, auto upgrade, for simplified user management and device maintenance. 5.2 System Login 5.2.1 Network Connection When parking detector is installed, you must inspect if it is well connected to the Internet or not.
  • Page 16 Figure 5- 1 Step 3. Input username and password. Default username is “admin” and password is “admin”. Click on Login. System shows Figure 5- 2 WEB live interface of parking detector, see Figure 5- 2 Parking detector WEB client operation refers to its WEB Operation Manual.
  • Page 17: Technical Specifications

    6 Technical Specifications Paramete Parameter Name Value r Type Model ITC114-PH1B ITC314-PH1B Sensor Type 1/3 inch CMOS Electronic 1/3s~1/10000s,may manually or auto adjust Shutter Camera Day/Night Electronic color to B/W White Balance Auto Image Compression JPEG Standard Image Image 1280×960 2304×1296...
  • Page 18 Paramete Parameter Name Value r Type Model ITC114-PH1B ITC314-PH1B Work Humidity 10%~90% Dimensions Ø 105mm×118mm Weight 0.5kg Installation Dome design, in-ceiling bridge mount...
  • Page 19: Faq

    7 FAQ Solution I cannot boot up Possible cause: the device. Incorrect input power. Poor contact of power line. Bad power adaptor. Program upgrading error. Device auto Possible cause: reboots or crash Unstable input voltage or low voltage. after boot up Insufficient ON/OFF power.
  • Page 20 Solution I cannot login via Possible cause: Internet. The connected user exceeds the limit. Your IP does not meet requirements in device Black/White list. Note:  This manual is for reference only. Slight difference may be found in the user interface.