Checking The System's Functionality; Decommissioning; Handing Over To The Operator; Replacement Parts And Accessories - Vaillant VED Operating And Installation Instructions

Electric instantaneous water heater
Table of Contents

Advertisement

5 Starting up/decommissioning
6 Handing over to the operator, 7 Replacement parts and accessories
5.3

Checking the system's functionality

> Connect the unit to the electrical mains.
The following output levels are available on the VED:
Output levels
Level 1 (low draw-off rate)
Level 1 (high draw-off rate)
Level 2 (low draw-off rate)
Level 2 (high draw-off rate)
Tab. 5.1 Adjustable output levels
– The temperature at level I with a high draw-off rate is
approx. 30 °C. This will reach approx. 60 °C at level II
with a low draw-off rate.
Fig. 5.3 Output selector switch
> Set the output selector to level I and draw off a small
volume of water.
> Check all 4 output levels that are specified in tab. 5.1.
5.4

Decommissioning

5.4.1
Taking out of service temporarily
The VED can be taken out of service temporarily, e.g. for
maintenance work.
> De-energise the unit.
> Close the cold water stop valve.
5.4.2 Taking out of service permanently
To shut down the VED permanently, proceed as follows:
> De-energise the unit.
> Close the cold water stop valve.
> Carefully loosen the cold and hot water connections.
> Capture the residual water (up to 0.4 litres) left inside
the unit using a suitable container.
> Remove the unit from its mounting.
14
Nominal output
1/3 of the nominal output
2/3 of the nominal output
1/2 of the nominal output
1/1 of the nominal output
Installation instructions for VED electric instantaneous water heater 0020149586_00
6

Handing over to the operator

a
Danger!
Risk of being scalded by hot water!
Above a water temperature of 43 °C, there is
a risk of scalding. When setting the output
regulator to level II, temperatures can reach
up to 60 °C.
> Inform the operator that there is a risk of
scalding above a water temperature of
43 °C.
> Recommend to the operator that, in normal
operating mode, the output selector is set
to level I to avoid scalding.
You must inform the operator of the unit about the han-
dling and function of their VED.
> Provide the operator with all relevant instructions and
unit documentation for safe-keeping.
> Go through the instructions for use with the operator.
> Answer any questions the operator may have.
> Draw special attention to the safety information
which the operator must follow.
> Inform the operator of the necessity to ensure that the
system is regularly inspected/maintained by a compe-
tent person (inspection and maintenance contract).
> Make the operator aware that the instructions should
be kept near the VED.
7

Replacement parts and accessories

The original components of the unit were also certified
as part of the CE declaration of conformity. If you do not
use certified Vaillant genuine spare parts, this voids the
CE conformity of the unit. We therefore strongly recom-
mend that you fit Vaillant genuine spare parts.
You can find information about available Vaillant genu-
ine spare parts from the contact address provided on
the reverse of this document.
> If you require spare parts for servicing or repair work,
use only Vaillant genuine spare parts.