Self-contained marine air
conditioning systems (40 pages)
Summary of Contents for Webasto NiteCool RCC-100
Page 1
NiteCool TCC-100/RCC-100 Standkühlanlage Betriebsanweisung Parking cooler system Operating Instructions Rafraîchisseur d'air Notice d’utilisation Raffrescatore a veicolo fermo Istruzioni per l’uso Enfriador evaporativo Indicaciones de funcionamiento Interieurkoeler Gebruiksinstructie 03/2007 9015539B...
Page 2
NEVER try to install or repair Webasto heating or cooling systems if you have not completed a Webasto training course, you do not have the necessary technical skills and you do not have the technical documentation, tools and equipment available to ensure that you can complete the installation and repair work properly.
NiteCool TCC-100/RCC-100 parking cooler system Contents Page Maintenance and safety instructions General Operation 3.1 Control elements 3.2 Control panel 3.3 Functions 3.4 Remote control 3.5 Air vents Malfunctions and possible remedies...
NiteCool TCC-100/RCC-100 parking cooler system Maintenance and safety 2. If the vehicle height stated in the vehicle 6. Irrespective of the schedule in the registration document is exceeded due to installation and service manual, check all instructions the installation of the parking cooler the attachments on the unit and the system, it must be legalised through a type connections to ensure that they are tight...
Risk of explosion if the batteries are by Webasto. The same applies if repairs If it is necessary to tilt the cab, first wait exchanged improperly! are carried out incorrectly or with the use...
Page 6
Leave the cab windows open during the Failure to follow the instructions will lead to cleaning process and make sure no-one all liability being refused by Webasto. remains in the cab. Clean the fresh water tank of mobile homes according to the vehicle manufacturer instructions.
NiteCool TCC-100/RCC-100 parking cooler system 3.3 Functions Cooling function ON/OFF switch Blower switch Pressing button 1 switches on the cooling ON/OFF switch Pressing button 1 increases the blower function of the parking cooler system, and setting. The parking cooler system is switched on/ the switch-on indicator LED 2 lights up.
Page 10
NiteCool TCC-100/RCC-100 parking cooler system Timer Low water level indicator Pressing button 1 increases the operating The cooling function is deactivated and the time of the parking cooler system and low water level indicator 1 lights up if there pressing button 2 reduces it. is insufficient water or a defect in the water Pressing button 1 once activates the timer pumping system.
NiteCool TCC-100/RCC-100 parking cooler system 3.4 Remote control 3.5 Air vents ON/OFF switch To enable the air vents to be directed according to individual requirements as Pressing button 1 switches on the parking much as possible, the air vents 1 can be cooler system.
NiteCool TCC-100/RCC-100 parking cooler system Malfunctions and possible remedies Symptom Possible cause Remedy No cooling power Water pumps not running Check the connection to the water pumps Check fuses Water level sensors are providing incorrect Check water level sensors information Clean water tank Water pipes kinked or squashed Remedy the cause of the fault, seal any leaks...
Page 13
NiteCool TCC-100/RCC-100 parking cooler system Page for notes...