Mitsubishi Electric PFFY-P20VLEM-A Technical & Service Manual page 17

Floor standing type indoor unit
Table of Contents

Advertisement

Switch Pole
SWA
1~3
Option
Note:1
1
SWC
2
2
Option
3
(SWA)
Note:1
SW11
1st digit
address
setting
SW12
SW12
2nd degit
address
setting
Note:2
SW14
Connect
ion No.
setting
Note:2
220V
SW5
Voltage
2
Selection
Note:2
Note
1:The DipSW setting is effective always after powering ( remote controller ON ) for SWA and SWC.
2:The DipSW setting is effective during unit stopping ( remote controller OFF ) for SW11,12,14 and 5
Operation by switch
3
As this switch is used by interlocking with
SWC,refer to the item of SWC for detail
2
1
(Option)
(Standard)
SWC
SW11
Address setting should be done when network
0
0
remote controller (PAR-F25MA) is being used.
10
1
SW14
This is the switch to be used when the indoor
0
unit is operated with R2 series outdoor unit as
a set.
If the unit is used at the 230V or 240V area,
240V
set the voltage to 240V.
If the unit is used at the 220V, set the voltage
to 220V.
When attach the optional high perfor-
mance filter elements (filter casement)
to the unit, be sure to attach it to the
option side in order to prevent the air-
flow reducing.
Remarks
Address board
<At delivery>
3
2
1
Address board
<At delivery>
(Option)
(Standard)
Address board
Address can be set while the
unit is stopped.
<At delivery>
SW12
SW11
0
0
Address board
<At delivery>
SW14
0
Address board
<At delivery>
220V
240V
16