Mitsubishi Electric CITY MULTI PFFY-P20VCM-E Installation Manual

Hide thumbs Also See for CITY MULTI PFFY-P20VCM-E:

Advertisement

<ORIGINAL>
Air-Conditioners

INDOOR UNIT

PFFY-P20,25,32,40,50,63VCM-E

INSTALLATION MANUAL

For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit.
INSTALLATIONSHANDBUCH
Zum sicheren und ordnungsgemäßen Gebrauch der Klimageräte das Installationshandbuch gründlich durchlesen.
MANUEL D'INSTALLATION
Veuillez lire le manuel d'installation en entier avant d'installer ce climatiseur pour éviter tout accident et vous assurer d'une utilisation correcte.
INSTALLATIEHANDLEIDING
Voor een veilig en juist gebruik moet u deze installatiehandleiding grondig doorlezen voordat u de airconditioner installeert.
MANUAL DE INSTALACIÓN
Para un uso seguro y correcto, lea detalladamente este manual de instalación antes de montar la unidad de aire acondicionado.
MANUALE DI INSTALLAZIONE
Per un uso sicuro e corretto, leggere attentamente questo manuale di installazione prima di installare il condizionatore d'aria.
ΕΓΧΕΙΡΙ∆ΙΟ Ο∆ΗΓΙΩΝ ΕΓΚΑΤΑΣΤΑΣΗΣ
Για ασφάλεια και σωστή χρήση, παρακαλείστε διαβάσετε προσεχτικά αυτό το εγχειρίδιο εγκατάστασης πριν αρχίσετε την εγκατάσταση της μονάδας κλιματισμού.
MANUAL DE INSTALAÇÃO
Para segurança e utilização correctas, leia atentamente este manual de instalação antes de instalar a unidade de ar condicionado.
INSTALLATIONSMANUAL
Læs venligst denne installationsmanual grundigt, før De installerer airconditionanlægget, af hensyn til sikker og korrekt anvendelse.
INSTALLATIONSHANDBOK
Läs den här installationshandboken noga innan luftkonditioneringsenheten installeras, för säker och korrekt användning.
MONTAJ ELKİTABI
Emniyetli ve doğru biçimde nasıl kullanılacağını öğrenmek için lütfen klima cihazını monte etmeden önce bu elkitabını dikkatle okuyunuz.
РЪКОВОДСТВО ЗА МОНТАЖ
За безопасна и правилна употреба, моля, прочетете внимателно това ръководство преди монтажа на климатизатора.
PODRĘCZNIK INSTALACJI
W celu bezpiecznego i poprawnego korzystania należy przed zainstalowaniem klimatyzatora dokładnie zapoznać się z niniejszym podręcznikiem instalacji.
INSTALLASJONSHÅNDBOK
For sikker og riktig bruk, skal du lese denne installasjonshåndboken nøye før du installerer klimaanlegget.
РУКОВОДСТВО ПО УСТАНОВКЕ
Для осторожного и правильного использования прибора необходимо тщательно ознакомиться с данным руководством по установке до выполнения установки кондиционера.
PŘÍRUČKA K INSTALACI
V zájmu bezpečného a správného používání si před instalací klimatizační jednotky důkladně pročtěte tuto příručku k instalaci.
NÁVOD NA INŠTALÁCIU
Pre bezpečné a správne použitie si pred inštalovaním klimatizačnej jednotky, prosím, starostlivo prečítajte tento návod na inštaláciu.
TELEPÍTÉSI KÉZIKÖNYV
A biztonságos és helyes használathoz, kérjük, olvassa el alaposan ezt a telepítési kézikönyvet, mielőtt telepítené a légkondicionáló egységet.
PRIROČNIK ZA NAMESTITEV
Za varno in pravilno uporabo pred namestitvijo klimatske naprave skrbno preberite priročnik za namestitev.
MANUAL CU INSTRUCŢIUNI DE INSTALARE
Pentru o utilizare corectă şi sigură, vă rugăm să citiţi cu atenţie acest manual înainte de a instala unitatea de aer condiţionat.
PRIRUČNIK ZA UGRADNJU
Radi sigurne i ispravne uporabe, temeljito pročitajte ovaj priručnik prije ugradnje klimatizacijskog uređaja.
คู  ม ื อ การติ ด ตั ้ ง
เพื ่ อ ให ส ามารถใช ง านได อ ย า งถู ก ต อ งและปลอดภ ั ย กรุ ณ าอ า นคู  ม ื อ การติ ด ตั ้ ง นี ้ อ ย า งละเอี ย ดก  อ นทํ า การติ ด ตั ้ ง เครื ่ อ งปรั บ อากาศ
安裝手冊
安裝本空調機之前,請仔細閱讀本安裝手冊,以便安全正確地使用。

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric CITY MULTI PFFY-P20VCM-E

  • Page 1: Indoor Unit

    <ORIGINAL> Air-Conditioners INDOOR UNIT PFFY-P20,25,32,40,50,63VCM-E INSTALLATION MANUAL For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit. INSTALLATIONSHANDBUCH Zum sicheren und ordnungsgemäßen Gebrauch der Klimageräte das Installationshandbuch gründlich durchlesen. MANUEL D’INSTALLATION Veuillez lire le manuel d’installation en entier avant d’installer ce climatiseur pour éviter tout accident et vous assurer d’une utilisation correcte. INSTALLATIEHANDLEIDING Voor een veilig en juist gebruik moet u deze installatiehandleiding grondig doorlezen voordat u de airconditioner installeert.
  • Page 2 [Fig. 3.1.1] (Unit: mm) For PFFY-P-VCM-E (mm) Model name · · More than 240 · More than 240 1100 More than 240 A Floor B Piping space C Electrical part service space [Fig. 4.1.1] [Fig. 4.1.2] For fixing on the floor <Viewed from top of the unit>...
  • Page 3 [Fig. 4.2.1] Floor hole for fixing [Fig. 5.2.1] (Unit: mm) 136.5 Refrigerant piping (liquid) Refrigerant piping (gas) Drain outlet [Fig. 6.1.1] [Fig. 6.1.3] Cut here Remove brazed cap Thermal insulation [Fig. 6.1.2] Pull out insulation Wrap with damp cloth Return to original position Ensure that there is no gap here Wrap with insulating tape Cool by a wet cloth...
  • Page 4 [Fig. 6.2.1] Downward slope 1/100 or more Drain hose (Accessory) Indoor unit Collective piping [Fig. 6.2.2] (Unit: mm) Indoor unit Tie band (accessory) Band fixing part Insertion margin Drain hose (accessory) Drain pipe (O.D. ø32 PVC TUBE, field supply) Insulating material (field supply) [Fig.
  • Page 5 [Fig. 8.2.1] [Fig. 8.2.2] M1M2 M1M2 M1M2 M1M2 M1M2 M1M2 TB15 TB5 TB15 Terminal block for indoor transmission cable Terminal block for outdoor transmission cable Remote controller [Fig. 8.2.3] [Fig. 8.2.4] DC10~13V Non-polarized TB15 Remote Controller DC24~30V (A, B) [Fig. 8.3.1] [Fig.
  • Page 6 [Fig. 8.6.1] SW21 SW14 SW12 SW11 <Indoor controller board>...
  • Page 7: Table Of Contents

    • Ask the dealer or an authorized technician to install the air conditioner. operated forcibly, or parts other than those specified by Mitsubishi Electric are - Improper installation by the user may result in water leakage, electric shock, or used, fire or explosion may result.
  • Page 8: Before Getting Installed

    1.4. Before getting installed (moved) - electrical work • Use refrigerant piping made of C1220 (Cu-DHP) phosphorus deoxidized copper as specified in the JIS H3300 “Copper and copper alloy seamless pipes and tubes”. In addition, be sure that the inner and outer surfaces of Caution: the pipes are clean and free of hazardous sulphur, oxides, dust/dirt, shav- •...
  • Page 9: Securing Installation And Service Space

    3.1. Securing installation and service space • Do not install unit at a site where fire detector is located at the supply air side. (Fire detector may operate erroneously due to the heated air supplied during For PFFY-P-VCM-E (mm) heating operation.) •...
  • Page 10: Connecting Refrigerant Pipes And Drain Pipes

    3. Perform insulation work on the drain pipe (O.D. ø32 PVC TUBE) and on the - It may also be in violation of applicable laws. socket (including elbow). - MITSUBISHI ELECTRIC CORPORATION cannot be held responsible for mal- [Fig. 6.2.2] (P.4) functions or accidents resulting from the use of the wrong type of refrigerant.
  • Page 11: Electrical Wiring

    8. Electrical wiring Precautions on electrical wiring 5. Never connect the power cable to leads for the transmission cables. Otherwise the cables would be broken. Warning: 6. Be sure to connect control cables to the indoor unit, remote controller, and the Electrical work should be done by qualified electrical engineers in accordance outdoor unit.
  • Page 12: Connecting Remote Controller, Indoor And Outdoor Transmission Cables

    *3 Current sensitivity is calculated using the following formula. G1 = (V2  Quantity of Type1) + (V3  Wire length [km]) Current sensitivity Wire thickness 30 or less 30 mA 0.1 sec or less 1.5 mm 100 or less 100 mA 0.1 sec or less 2.5 mm 4.0 mm...
  • Page 13: External I/O Specifications

    8.4. External I/O specifications Caution: 1. Wiring should be covered by insulation tube with supplementary insulation. 2. Use relays or switches with IEC or equivalent standard. 3. The electric strength between accessible parts and control circuit should have 2750 V or more. 8.5.
  • Page 15 ±10 IP20 R410A 4.15...
  • Page 16 This product is designed and intended for use in the residential, commercial and light-industrial environment. The product at hand is • Low Voltage Directive 2014/35/EU based on the following • Electromagnetic Compatibility Directive EU regulations: 2014/30/EU • Machinery Directive 2006/42/EC Please be sure to put the contact address/telephone number on this manual before handing it to the customer.

Table of Contents