HEIDENHAIN iTNC 530 User Manual page 395

Nc software 606420-04 sp8 606421-04 sp8 606424-04 sp8 606425-04 sp8
Hide thumbs Also See for iTNC 530:
Table of Contents

Advertisement

Danger of collision!
When dynamic collision monitoring (DCM) is active, the
TNC might move the tool only until it detects a collision
and, from there, complete the NC program without any
error message. This can result in tool paths different from
those programmed!
Suppressing touch probe monitoring: M141
Standard behavior
When the stylus is deflected, the TNC outputs an error message as
soon as you attempt to move a machine axis.
Behavior with M141
The TNC moves the machine axes even if the touch probe is
deflected. This function is required if you wish to write your own
measuring cycle in connection with measuring cycle 3 in order to
retract the stylus by means of a positioning block after it has been
deflected.
Danger of collision!
If you use M141, make sure that you retract the touch
probe in the correct direction.
M141 functions only for movements with straight-line
blocks.
Effect
M141 is effective only in the block in which it is programmed.
M141 becomes effective at the start of block.
HEIDENHAIN iTNC 530
395

Advertisement

Table of Contents
loading