Display - Instrutech CVM211 User Manual

Convection vacuum gauge module the stinger
Hide thumbs Also See for CVM211:
Table of Contents

Advertisement

Instruction Manual

Display

6
The table below shows the displayed readings at various pressures for selected gases.
Pressures shown in bold italic font in the shaded areas are in x 10
Pressures shown in normal font and in non-shaded areas are in mbar. Note only the green LED is illuminated.
Pressures shown in normal bold font with an asterisk(*) in the shaded areas are in bar. Note only the red LED is illuminated.
True
Pressure
N
-3
0
x 10
mbar
0.0
-3
0.1
x 10
mbar
0.1
-3
0.3
x 10
mbar
0.3
-3
0.6
x 10
mbar
0.6
-3
1.33
x 10
mbar
1.3
-3
2.67
x 10
mbar
2.7
-3
6.67
x 10
mbar
6.7
-3
13.3
x 10
mbar
13.3
-3
26.6
x 10
mbar
26.6
-3
66.6
x 10
mbar
66.6
0.13
mbar
0.13
0.26
mbar
0.26
0.66
mbar
0.66
1.33
mbar
1.33
2.66
mbar
2.66
6.66
mbar
6.66
13.3
mbar
13.3
26.6
mbar
26.6
66.6
mbar
66.6
133
mbar
133
266
mbar
266
400
mbar
400
533
mbar
533
666
mbar
666
800
mbar
800
933
mBar
933
1.01
Bar
1.01*
1.06
Bar
1.06*
1.19
Bar
1.19*
1.33
Bar
1.33*
Notes: OP = Overpressure indication; display will read 1.33 bar.
Examples:
1) Gas used is nitrogen. Display shows pressure measurement of 13.3 mbar. True pressure of nitrogen is 13.3 mbar.
2) Gas used is argon. Display shows pressure measurement of 11.7 mbar. True pressure of argon is 133 mbar.
3) Gas used is CO
. Display shows pressure measurement of 73.1 x 10
2
mbar.
InstruTech
Displayed Pressure Readings vs. True Pressure for selected gases
Ar
He
O
2
2
0.0
0.0
0.0
0.1
0.1
0.1
0.3
0.3
0.3
0.6
0.6
0.6
0.9
1.06
1.33
1.86
2.13
2.66
4.40
5.33
6.66
8.79
10.7
12.9
17.4
21.4
26.3
43.1
53.9
65.5
85.7
0.11
0.12
0.16
0.21
0.25
0.41
0.57
0.64
0.79
1.25
1.29
1.51
2.95
2.58
3.26
17.9
6.63
5.33
OP
13.7
7.73
OP
29.7
10.4
OP
103
11.7
OP
278
13.0
OP
393
15.0
OP
506
17.9
OP
646
21.4
OP
805
25.0
OP
973
29.0
OP
1.14*
31.5
OP
1.25*
33.4
OP
1.32*
37.9
OP
OP
43.3
OP
OP
-3
mbar. Note both the green and red LEDs are illuminated.
CO
KR
Freon12
2
0.0
0.0
0.0
0.1
0.1
0.1
0.3
0.3
0.3
0.6
0.4
0.6
1.46
0.5
2.00
3.06
1.33
4.13
5.86
3.06
10.1
14.6
6.39
19.5
29.5
12.6
39.8
73.1
31.3
96.6
0.14
62.3
0.19
0.27
0.12
0.36
0.65
0.28
0.81
1.26
0.53
1.39
2.27
0.93
2.15
4.45
1.70
3.26
6.62
2.37
3.94
8.78
3.05
4.42
10.9
3.42
5.05
12.3
3.65
6.23
16.3
4.42
7.98
22.5
4.78
9.18
29.8
5.25
10.1
38.2
5.61
11.0
48.5
5.91
11.8
61.4
6.19
12.5
71.8
6.33
13.0
79.1
6.45
13.2
105
6.65
13.9
147
6.77
14.7
-3
mbar. True pressure of CO
CVM211 Stinger
Freon22
D
Ne
2
0.0
0.0
0.0
0.1
0.1
0.1
0.3
0.3
0.3
0.6
0.6
0.6
2.00
1.73
0.9
4.13
3.19
2.00
9.33
7.99
4.66
17.9
16.1
9.46
36.2
32.3
18.7
91.9
79.9
46.3
0.18
0.16
0.1
0.34
0.33
0.18
0.79
0.91
0.47
1.38
2.06
0.99
2.21
5.5
2.11
3.49
327
6.98
4.51
OP
28.6
4.95
OP
778
5.51
OP
OP
6.54
OP
OP
8.55
OP
OP
10.0
OP
OP
11.2
OP
OP
12.2
OP
OP
13.2
OP
OP
14.2
OP
OP
14.7
OP
OP
15.1
OP
OP
16.0
OP
OP
16.9
OP
OP
is 66.6 x 10
2
CH
4
0.0
0.1
0.3
0.6
2.26
4.39
10.2
20.3
40.5
0.10
0.21
0.41
1.04
2.13
4.43
10.0
37.1
473
1.12*
OP
OP
OP
OP
OP
OP
OP
OP
OP
OP
OP
-3
Page 18