Return
Skip
76/7560 S/H
Electrical Changes
•The electrical settings must be changed according to the procedure below when mechanical changes
have been made.
•After changing the electrical settings, select the cassette that has been changed using the
CASSETTE key, and make sure that the LED for the set paper size lights.
(1) When setting by entering a code
<Key Operation>
0
8
POWER
↓
DEGITAL KEYS : Enter the code (select the cassette)
↓
PRINT
↓
DEGITAL KEYS
: Enter the setting of the new paper size.
↓
INT
: Store the new paper size setting value (ZZ) in the memory.
↓
:Cancel adjustment
0
9
mode.
(2) When setting by touch panel
<Key Operation>
Cassette select key
: Select cassette.
↓
Program
: Change to program mode selection screen.
↓
Cassette select icon
: Change to cassette size specification screen.
↓
: Press key of new paper size.
Paper size key
↓
END
65/5560 ADJUSTMENT
<Display, Supplementary Explanation>
TEST MODE D
Setting value of selected cassette
Paper Size Setting Value
Paper Size Setting Value
A5-R
1
Insert sheet
B5,ST-R
2
LT
3
FOLIO,COMP
A4
4
B5-R
5
LT-R
6
A4-R
7
SYSTEM MODE
TEST MODE D
2-59
100%
D
XX
SYSTEM MODE
8
Cover
9
10
LG
11
B4
12
LD
13
A3
14
New setting value is displayed
↓
XX
ZZ
YY
100%
100%
D
MAY.1997 © TOSHIBA CORP.
Cassette Code
LCF
31
Upper
32
Middle
33
Lower
34
↓
XX
YY
100%