Important; Australia And New Zealand - Miele PG 8536 Operating Instructions Manual

Washer-disinfector
Table of Contents

Advertisement

IMPORTANT

Australia and New Zealand

This appliance must be installed
according to AS/NZS 3500.1.
This appliance has been supplied
with a separate backflow prevention
device.
This machine must be connected to the
potable water supply via the non-return
valve (check valve) supplied with the
machine.
Before making plumbing connections,
ensure the appliance is disconnected
from the main power supply (switch off
or unplug the power).
^ Turn off the mains water tap.
^ Place the seals on both sides of the
non-return valve.
^ Connect the female end of the
non-return valve to the water tap.
^ Connect the filter to the male end of
the non-return valve.
^ Connect the inlet hose to the filter.
Ensure that all connections are
screwed into position correctly. The
connection points are subject to mains
water pressure.
^ Turn on the tap slowly and check for
leaks.
Correct the position of the seal and
union if necessary.
Plumbing
69

Hide quick links: