Installation and Tapping –
Connecting the Regulator to the
CO
Cylinder
2
Remove blue plug from regulator fitting.
(Note: Do not remove the carbonic washer).
Screw regulator onto gas cylinder valve. Tighten
with wrench until vertically straight. Be sure that
shut-off valve (black lever) on regulator is in
the OFF (horizontal) position.
Place a screw clamp over end of red air line
and push onto regulator tailpiece. Tighten clamp
with a screwdriver.
REGULATOR
FITTING
CO2
PRESSURE
GAUGE
30
20
40
PERLICK
10
50
PSI
60
0
FITTING FOR
RED AIR HOSE
SHUT-OFF VALVE
(BLACK LEVER IN
CLOSED POSITION)
Adjusting the CO
2
Turn regulator adjusting screw counterclockwise
until it turns freely.
Turn hand valve counterclockwise on CO
cylinder to the fully open position.
Turn regulator adjusting screw clockwise until
desired pressure is reached (approximately
12-15 lbs.). Tighten stop nut on adjusting screw.
Open shut-off valve on bottom of regulator.
CO
Leak Test
2
Dilute a small amount of liquid dishwashing soap
and rub the soapy mixture around each connection.
If bubbles appear, tighten connection.
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
HAND
VALVE
CO2
GAS
DRUM
REGULATOR
ADJUSTING
SCREW
Gas Flow
2
Direct Draw Dispensers Self-Contained
Replacing CO
Turn CO
hand valve clockwise until seated and
2
close shut-off valve on regulator.
Unscrew regulator from cylinder fitting.
Replace carbonic washer (Part No. 157F2P),
if needed and reattach regulator to filled
cylinder.
Turn CO
hand valve counterclockwise until
2
fully open. Turn regulator shut-off valve to
open position.
Adjust CO
2
clockwise for higher pressure.
Proper CO
2
...
ALWAYS
Connect a regulator (reducing valve) to
CO
cylinder.
2
Secure cylinder in upright position whether in
storage or in use.
Keep cylinder away from heat. Rupture disc
vents at 122° F. maximum.
Ventilate room after high pressure gas leakage.
Check the last DOT test date on cylinder neck
before filling. If more than five years old, the
cylinder must be retested to DOT specifications.
Be sure CO
or dirt before attaching regulator.
Store CO
cylinder and regulator assembly
2
upright.
Allow only properly trained and experienced
personnel to handle high pressure gas.
...
NEVER
Connect cylinder directly to a keg without a
regulator (reducing valve).
Drop or throw regulator or CO
Transport CO
Apply oil to a regulator.
Shut off CO
not save gas by doing so!
Allow untrained, inexperienced personnel to
handle high pressure gas.
Failure to heed this warning could result in
personal injury or death.
5
Gas Cylinder
2
gas flow as required, turning
Handling
cylinder outlet fitting is free of dust
2
cylinder.
2
cylinder in a closed vehicle.
2
cylinder when not in use. You will
2
Form No. Z2280

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds32Ds60bDs72bDs84bDs60sDs72s ... Show all

Table of Contents