Trouble-Shooting Guide
Minor problems can often be solved by the appliance owner. Please refer to this trouble-
shooting guide for the possible cause and solution to your problem. Should the problem still
persist, please contact the closest authorized service agent in your area for assistance.
The Appliance fails to Operate After Connecting to Electrical Power Supply
•
Check the power cord is properly connected.
•
Check the power supply in the electrical outlet (blown fuse / circuit breaker).
•
Make sure the appliance is working.
Continuous Operation of the Cooling System
•
The door is frequently opened or left open for too long.
•
The door is not properly closed (the door may sag, the gasket may be polluted or
damaged).
•
Perhaps you may have overloaded the appliance with fresh food.
•
The reason may be inadequate ventilation of the compressor (assure adequate air
circulation).
Ice Formation on the Inner Rear Wall
As long as the defrost water runs to the channel and through the outlet to the drain pan on the
compressor, automatic defrosting of the appliance is assured. In case ice formation on the inner
back wall is increased (3-5mm), ice should be manually defrosted.
•
Disconnect the appliance from the power supply and leave the door open. Never use
electric devices for defrosting and do not scrape the ice of frost layer with sharp objects.
•
After defrosting is complete close the refrigeration door, and reconnect to power supply.
The cause of increased ice formation may be one of the following:
•
the door does not seal well (clean the gasket if it is contaminated, or replace
it if it is damaged)
•
the door is frequently opened or left open for too long
•
the food stored in the refrigerator was warm
•
the food or dish is touching the inner back wall.