II. Installation Instructions
®
A. Legend
II Components
®
The Legend
II Box Contains:
1. Cleaner Head
2. Sand & Silt Bag
3. Sweep Hose
4. Complete Feed Hose
a. 1 - 18 in. hose
b. 1 - 2 ft. hose
c. 1 - 4½ ft. hose
d. 3 - 6 ft. hoses
e. 1- Back-Up Valve
f. 4 - Swivels
g. 1 - Wall Fitting
h. 12 - Mender Nuts
i. 7 - Hose Floats
j. 1 - Pressure Tester
LEGEND® II INSTALLATION MANUAL
B. Pool Connections
®
The Legend
II comes equipped to connect to a
female threaded 1-1/2" dedicated return line. An
adjustable gate valve with a pressure gauge should
be installed to allow a regulated amount of water flow
from your pool system to the Legend
information contact our Technical Support
Department at 1-800-831-7133.
Also, if the pool doesn't have a dedicated cleaner
line please contact our Technical Support
Department also.
C. Installing the Twist Lock Pressure
Relief Valve (Wall Fitting)
1. Take out any existing pool cleaner and/or wall
fitting.
2. Turn on the filtration pump and flush out the
plumbing line.
3. Turn off filter pump
4. Remove the Wall Adapter from the Wall Fitting
and screw Adapter by hand into the dedicated
line. Turn until tight.
5. Take the Wall Fitting and Twist Lock the Wall Fitting
into the Wall Adapter 1/4 turn; to a snug fit. Once
the Wall Adapter is secure you can now twist lock
and unlock to remove Wall Fitting with ease from
the Wall Adapter.
®