Mode and Action
Replacing Lost Tags
1.
Delete the lost Tag from its Tag
Location. (See the "Deleting Tags"
section).
2.
Add the new Tag to the abovementioned
Tag Location. (See the relevant "Adding
Tags" section).
Set Relay Durations
In Run Mode press the "ADD" Push-
1.
button for longer than 1 second.
Press the "TENS" and "UNITS" Push-
2.
buttons to specify the duration of Relay 1
in seconds (00 = Toggled Mode).
NOTE: The factory default setting is 01.
Press the "ADD" Push-button for less
1.
than 1 second.
Press the "TENS" and "UNITS" Push-
2.
buttons to specify the duration of Relay 2
in seconds (00 = Toggled Mode).
NOTE: The factory default setting is 01.
Press the "ADD" Push-button for less
1.
than 1 second.
Press the "TENS" and "UNITS" Push-
2.
buttons to specify the duration of Relay 3
in seconds (00 = Toggled Mode).
NOTE: The factory default setting is 01.
Press the "ADD" Push-button for less
1.
than 1 second.
Press the "TENS" and "UNITS" Push-
2.
buttons to specify the duration of Relay 4
in seconds (00 = Toggled Mode).
NOTE: The factory default setting is 01.
Press "ADD" for less than 1 second to go
3.
back to Run Mode.
SGI300-0-0-GB-08
7-Segment Display LED
Displays
Displays the first free
Location
Displays selected Tag
Memory Location
Displays the Relay
Drive Time in seconds
(01–99 seconds)
Displays the Relay
Drive Time in seconds
(01–99 seconds)
Displays the Relay
Drive Time in seconds
(01–99 seconds)
Displays the Relay
Drive Time in seconds
(01–99 seconds)
April 2008
(01-99)
Display
Duration
2 seconds
1 second
1 second
1 second
1 second
Page 10

Advertisement

loading