Diagramme en échelle du schéma électrique du chauffe-piscine/spa
DIAGRAMME EN ESCALIER
SOUS
TENSION
DISPOSITIF D'ALLUMAGE
L1
S1
F1
C. a. 24 V
24V
COM NO
M ANOSTAT D'EAU
VAL
INTERRUPTEUR D'ARRÊT
AUTOM ATIQUE DU GAZ
CAPTEUR
THERMOSTATIQUE
NOTA:
1.)
L1
S2
SONT BRAN CHÉS SUR LE MODULE D'INFLA MM ATION
2. )
CONNE CTEUR À BROCHES ET À DOUILLES.
SI UN DES FILS D'ORIGINE LIVRÉS AVEC CET APPAREIL
3. )
DOIT ÊTRE REMPLACÉ, LE REMPLACER PAR UN FIL DE
TYPE 105C OU UN FIL ÉQUIVALENT.
C. a. 120 V
S2
L2
F2
SOUFFLANTE
TERRE
C. a. 120 V
TRANSFO RMATEUR
DE CATÉGORIE II
C. a. 24 V
COMM AN DE DE
FONCIONNE M ENT
C. a. 24 V
TERRE
LOGIQUE
CONTA CTEUR DU
DÉBIT D'AIR
INTERRUPTEUR
À M AXIM UM
IND
SOUPAPE À GAZ
CAPTEUR
DU CON DUIT
DES GAZ
L2
F1
F2
S1
24 VAC
GND
IND
VAL
TH
3662 0200 FR