Intertek ACVC96 Service Instructions Manual page 70

34.5" chassis
Table of Contents

Advertisement

SERVICING
WARNING
D
ISCONNECT ELECTRICAL POWER AND SHUT OFF GAS SUPPLY.
1. After turning off gas to furnace at the manual gas shutoff
valve external to the furnace, remove burner compart-
ment door to gain access to the gas valve.
2. Connect a calibrated water manometer (or appropriate
gas pressure gauge) at either the gas valve inlet pres-
sure tap or the gas piping drip leg as shown in the follow-
ing figures.
NOTE: At either location, a hose fitting must be installed
prior to making the hose connection.
NOTE: Use adapter kit #0151K00000S to measure gas pres-
sure on White-Rodgers 36J54 gas valves.
GAS LINE
GAS SHUTOFF VALVE
DRIP LEG CAP
WITH FITTING
MANOMETER HOSE
Measuring Inlet Gas Pressure
(Alternate Method)
3. Turn ON the gas and electrical power supply and oper-
ate the furnace and all other gas consuming appliances
on the same gas supply line.
4. Measure furnace gas supply pressure with burners fir-
ing. Supply pressure must be within the range specified
in the following table.
INLET GAS SUPPLY PRESSURE
Natural Gas
Minimum: 4.5" w.c.
Propane Gas
Minimum: 11.0" w.c.
If supply pressure differs from above, make necessary ad-
justments to pressure regulator, gas piping size, etc., and/
or consult with local gas utility.
70
GAS LINE
TO FURNACE
OPEN TO
ATMOSPHERE
MANOMETER
Maximum: 10.0" w.c.
Maximum: 13.0" w.c.
HIGH VOLTAGE
D
ALL
ISCONNECT
ELECTRICAL POWER AND SHUT OFF GAS
SUPPLY BEFORE SERVICING OR INSTALLING THIS UNIT.
M
ULTIPLE POWER SOURCES MAY BE PRESENT.
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
5. Disconnect manometer after turning off gas at manual
shutoff valve. Reinstall plug before turning on gas to fur-
nace.
6. Turn OFF any unnecessary gas appliances started in
step 3.
7. Turn on gas to furnace and check for leaks. If leaks are
found, repair and then reinstall burner compartment door.
8. Turn on electrical power and verify proper unit operation.
HIGH VOLTAGE
D
ALL
ISCONNECT
ELECTRICAL POWER AND SHUT OFF GAS
SUPPLY BEFORE SERVICING OR INSTALLING THIS UNIT.
M
ULTIPLE POWER SOURCES MAY BE PRESENT.
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
Gas Manifold Pressure Measurement and Adjust-
ment
Natural Gas Adjustments
HIGH VOLTAGE
D
ALL
ISCONNECT
ELECTRICAL POWER AND SHUT OFF GAS SUPPLY
BEFORE SERVICING OR INSTALLING.
NOTE: Use apapter kit #0151K00000S to measure gas pres-
sure on White-Rodgers 36J54 gas valves.
Only small variations in gas pressure should be made by
adjusting the gas valve pressure regulator. The manifold pres-
sure must be measured with the burners operating. To mea-
sure and adjust the manifold pressure, use the following pro-
cedure.
1. After turning off gas to furnace at the manual gas shutoff
valve external to the furnace, remove burner compart-
ment door to gain access to the gas valve.
2. Connect a calibrated water manometer (or appropriate
gas pressure gauge) at the gas valve outlet pressure
tap. Refer to Measuring Gas Pressure: Two-Stage Valves
figure for two-stage gas valve outlet pressure tap con-
nections.
WARNING
F
AILURE TO
WARNING
F
AILURE TO
WARNING

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Amvc96Gcvc96Gmvc96

Table of Contents