SYSTEM OPERATION
S
T
YSTEM
ROUBLESHOOTING
NOTE: Refer to the instructions accompanying the ComfortNet compatible outdoor AC/HP unit for troubleshooting information.
Refer to the Troubleshooting Chart for a listing of possible furnace error codes, possible causes and corrective actions.
LED
LED
Status
Off
1 Flash
Red
Communications
LED
2 Flashes
Off
1 Steady
Flash
Green Receive
LED
Rapid
Flashing
On Solid
Indication
Possible Causes
Normal condition
None
Communications
Communications
Failure
Failure
Out-of-box reset
Control power up
Learn button
depressed
No power
No power to furnace
Communications
Open fuse
error
Communications error
No network found
Broken/ disconnected
data wire(s)
Furnace is installed as
a legacy/ traditional
system
Normal network
Control is "talking" on
traffic
network as expected
Data 1/ Data 2
Data 1 and data 2
miss-wire
wires reversed at
furnace, thermostat,
or CT™ compatible
outdoor AC/HP
Short between data 1
and data 2 wires
Short between data 1
or data 2 wires and R
(24VAC) or C (24VAC
common)
ComfortNet™ System
Corrective Action(s)
Notes & Cautions
None
None
Depress Learn Button
Depress once
quickly for a power-
Verify that bus BIAS
up reset
and TERM
dipswitches are in the
Depress and hold
ON position.
for 2 seconds for
an out-of-box reset
None
None
Check fuses and
Turn power OFF
circuit breakers;
prior to repair
replace/reset
Replace blown fuse
Check for shorts in
low voltage wiring in
furnace/system
Reset network by
depressing learn
button
Check data 1/ data 2
voltages
Check
Turn power OFF
communications
prior to repair
wiring (data 1/ data 2
Verify wires at
wires)
terminal blocks are
Check wire
securely twisted
connections at
together prior to
terminal block
inserting into
terminal block
Verify furnace
installation type
Verify data1 and
(legacy/ traditional or
data voltages as
communicating)
described above
Check data 1/ data 2
voltages
None
None
Check
Turn power OFF
communications
prior to repair
wiring (data 1/ data 2
Verify wires at
wires)
terminal blocks are
Check wire
securely twisted
connections at
together prior to
terminal block
inserting into
terminal block
Check data 1/ data 2
voltages
Verify data1 and
data voltages as
described above
55