Intertek ACVC96 Service Instructions Manual page 49

34.5" chassis
Table of Contents

Advertisement

TROUBLESHOOTING
Symptoms of Abnormal
Diagnostic/
Operation (Legacy
Status LED
& ComfortNet™
Codes
Thermostat)
b4
• Furnace fails to operate.
• Integrated control
module LED display
provides b4 error code.
• ComfortNet™ thermostat
"Call for Service" icon
illuminated.
• ComfortNet™ thermostat
scrolls "Check Furnace"
message.
• Furnace fails to operate.
b5
• Integrated control
module LED display
provides b5 error code.
• ComfortNet™ thermostat
"Call for Service" icon
illuminated.
• ComfortNet™ thermostat
scrolls "Check Furnace"
message.
• Furnace fails to operate.
b6
• Integrated control
module LED display
provides b6 error code.
• ComfortNet™ thermostat
"Call for Service" icon
illuminated.
• ComfortNet™ thermostat
scrolls "Check Furnace"
message.
• Furnace fails to operate.
b7
• Integrated control
module LED display
provides b7 error code.
• ComfortNet™ thermostat
"Call for Service" icon
illuminated.
• ComfortNet™ thermostat
scrolls "Check Furnace"
message.
• Furnace operates at
b9
reduced performance or
operates on low stage
when high stage is
expected.
• Integrated control
module LED display
provides b9 error code.
ComfortNet™
Thermostat Only
Fault Description
Message
Circulator blower
MOTOR
motor senses
TRIPS
a loss of rotor
control.
• Circulator blower
motor senses
high current.
MOTOR LCKD
• Circulator blower
ROTOR
motor fails to start
10 consecutive
times.
MOTOR
Circulator blower
VOLTS
motor shuts down
for over or under
voltage condition.
Circulator blower
motor shuts
down due to
over temperature
condition on
power module.
MOTOR
Circulator blower
PARAMS
motor does not
have enough
information to
operate properly.
Motor fails to start
40 consecutive
times.
LOW ID
Airflow is lower
AIRFLOW
than demanded.
Possible Causes
Code
b4
b5
b6
b7
B9
• Blocked filters.
• Restrictive ductwork.
• Undersized ductwork.
Corrective Actions
Notes & Cautions
• Turn power OFF prior
to repair
• Turn power OFF prior
to repair.
• Replace motor with
correct replacement
part.
• Replace wheel with
correct replacement
part.
• Turn power OFF prior
to repair
• Check filters for
• Turn power OFF prior
blockage. Clean filters
to repair.
or remove obstruction.
• Check ductwork for
blockage. Remove
obstruction. Verify all
registers are fully open.
• Verify ductwork is
appropriately sized for
system. Resize/replace
ductwork if necessary.
49