Unpacking; Leveling; Diagram 1; Unit Location - Cornelius 500 SERIES Service Manual

Modular cubed ice maker
Hide thumbs Also See for 500 SERIES:
Table of Contents

Advertisement

" .
1
"
UNPACKING
,
"
L
1.
Uncrate machine and/or bin by re-
I
moving the staples from around the
bottom of cardboard crate and lift
off.
2.
Remove bolts fastening the crate skid
t o the bottom of the unit. If auxiliary
legs have been purchased for
the
bin, they should be installed at this
time.
LEVELING
If legs are used, adjust the leveling
legs of the storage bin until the unit is
level and all four (4) legs are
in
solid
contact with the floor.
Leveling is
very
important to
obtain
proper
draining and to maintain the proper
level in the water pan of the ice cu-
ber.
NOTE: If the bin is to be installed flush to
the floor, the machine must be sealed to the
floor with an approved mastic such
as Daw
)
R.T.V.
#732,
734, or G.E. #102, 108. This
is an
N.S.F.
requirement and is
the
responsibility of the installer.
UNIT LOCATION
1
Allow at least a minimum of six (6)
inches at the rear and side of the ice
machine for proper air circulation.
2.
This unit has been designed t o be in-
stalled in an indoor location which is
clean and which can be adequately
ventilated.
The
air
and water
temperatures should never exceed
looo
F or fall below 50°
F.
(Temperatures above
looo
F
will cut
the ice making capacity below an
economical
level.
Temperatures
below SOo F will cause a malftpction
of thermostatic sensors).
3.
The unit should
be located where air
circulation is not restricted. The unit
should not be located near a kitchen
grill.
Air which contains grease va-
pors will deposit grease on the con-
denser.
The condenser should al-
ways be kept clean.
UNIT
SET-UP
1.
Take off front panel of machine and
remove hardware bag or service
manual envelope with the water
strainer enclosed.
2.
Mount the ice maker to the top of the
ice storage bin or adapter in the
proper position over the ice drop
opening. The ice maker must then be
sealed both on the outside and the
inside bottom edges with an ap-
proved N.S.F. mastic such as
Dow
R.T.V. #732, 734, or
G.E.
R.T.V.
#102, 108.
This is and
N.S.F.
requirement and the responsibility of
the installer.
3.
Remove shipping tape from evapora-
tor curtains.
Diagram
1
3

Advertisement

Table of Contents
loading

Table of Contents