Use The Continuous Drainage Option From The Middle Hole - Gree GPC12AL-K3NNA1A Service Manual

Table of Contents

Advertisement

● Drainage way as follows.
1. In Cool, Dry or Heat mode operating, the condensation water will be drained to the chassis.(As show in Fig.6)
2. When the chassis is full with water, the buzzer will give out 8 sounds and "H8" is displayed to remind user to discharge water:
● Move the unit to a suitable place for discharging water; do not tilt the unit and keep it horizontal during moving;
● Take the drainage pipe from the clip and pull out the rubber plug on the drainage pipe to discharge water;
● Put back the rubber plug onto drainage pipe after finishing dischargeing and then fix the pipe on the clip;
● After full water protection is eliminated and the compressor has been stopped for 3 minutes, the unit will resume operation.

2.Use the continuous drainage option from the middle hole

NOTICE:Water can be automatically emptied into a floor drain by attaching 14mm inner diameter hose (not included).
(1) Remove the continuous drain cap 1 by turning it counter clockwise then remove the rubber stopper 2 from the spout. (As show
in Fig.7)
(2) Screw the drain connector to(included in the package) the spout by turning clockwise.(As show in Fig.8)
(3) Insert the drainage hose into drain connector.(As show in Fig.9)
Fig.8
ATTENTION:
When using continuous drainage option from the middle hole, place portable on a level surface and make sure garden hose is clear
of any obstructions and is directed downward. Placing portable on an uneven surface or improper hose installation may result in
water filling up the chassis and causing the unit to shut off. Empty water in the chassis if shut off occurs, then check portable location
and hose for proper setup.
24
Fig.6
Fig.7
Fig.9