Q4X Stainless Steel Laser Sensor with Dual Discrete Outputs and IO-Link
Performance Curves—Flush Mount Models
Minimum Separation Distance Between Target and Background for: Uniform and Non-Uniform Targets
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0
0
25
35
22
20
18
16
14
12
10
8
6
4
2
0
0
25
50
75
100
35
22
20
18
16
14
12
10
8
6
4
2
0
0
100
200
35
Dual Mode Reference Surface Considerations
Optimize reliable detection by applying these principals when selecting your reference surface, positioning your sensor
relative to the reference surface, and presenting your target. The robust detection capabilities of the Q4X allows successful
detection even under non-ideal conditions in many cases. Typical reference surfaces are metal machine frames, conveyor
P/N 190073 Rev. E
110 mm Models
Matte targets with a non-uniform
reflectivity: 6% to 90%
Matte targets with uniform
reflectivity: 6% to 90%
50
75
100
Distance to Target (mm)
Dimension X
310 mm Models
Matte targets with a non-uniform
reflectivity: 6% to 90%
Matte targets with uniform
reflectivity: 6% to 90%
125
150
175
200
225
250
Distance to Target (mm)
Dimension X
610 mm Models
Matte targets with a non-uniform
reflectivity: 6% to 90%
Matte targets with uniform
reflectivity: 6% to 90%
300
400
500
Distance to Target (mm)
Dimension X
Figure 15. Minimum Object Separation Distance (90% to 6% reflectance)
www.bannerengineering.com - Tel: +1-763-544-3164
Flush Mount Models
X
110
125
275
300
325
310
600
610
Target
Background
Y
Switch Point
Distance
11