Setting The Dcf77 Time Code Clocks - hopf 7406RC Technical Manual

Slave clock control board for system 7001rc
Table of Contents

Advertisement

A
DMINISTRATION OF THE
nd
2
Row:
ST
T:12.56.56
NEW ST:~
NEW T: ~~.~~.~~
To set the slave lines to the current time (e.g. on first installation or after maintenance work)
the slave line time must be re-entered. Care should be taken to ensure that all clocks
connected to the line are displaying the same time (e.g. 12.00.00). This time is then entered
under NEW T:.
6.7

Setting the DCF77 Time Code Clocks

DCF77 time code clocks are self-setting clocks. In order to set the clocks, a DCF77 data
telegram is required, which is transmitted via the line cables.
The DCF77 time code clocks set themselves automatically as soon as the DCF77 time
telegram has been successfully read in. The DCF77 time telegram and power supply are
transmitted via the cable lines.
22 / 27
hopf
Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
B
7406RC
OARD
Display status of the selected slave line (R = Run und S = Stop)
Current time of the selected line
Set the status of the selected line with the R and S keys;
confirm with the ENT key.
S = Stop  The whole line is stopped (the line time ceases to run in
the system 7001RC)
R = Run  The whole line is started and is set to the system time
using the line time displayed.
Set the new line time (00.00.00 – 23.59.59);
confirm with the ENT key.
The line is automatically re-started after the new slave line time has been re-
entered, even if the line has previously been stopped.