Panasonic kw9m User Manual page 60

Eco-power meter
Hide thumbs Also See for kw9m:
Table of Contents

Advertisement

Data register
008CH <LSB>
Instantaneous active
power (1)
008DH <MSB>
008EH <LSB>
Instantaneous active
power (2)
008FH <MSB>
0090H <LSB>
Instantaneous active
power (3)
0091H <MSB>
0092H <LSB>
Total instantaneous
active power
0093H <MSB>
0094H <LSB>
Instantaneous reactive
power (1)
0095H <MSB>
0096H <LSB>
Instantaneous reactive
power (2)
0097H <MSB>
0098H <LSB>
Instantaneous reactive
power (3)
0099H <MSB>
009AH <LSB>
Total instantaneous
reactive power
009BH <MSB>
009CH <LSB>
Instantaneous apparent
power (1)
009DH <MSB>
009EH <LSB>
Instantaneous apparent
power (2)
009FH <MSB>
00A0H <LSB>
Instantaneous apparent
power (3)
00A1H <MSB>
00A2H <LSB>
Total instantaneous
apparent power
00A3H <MSB>
00A4H <LSB>
Voltage 1
00A5H <MSB>
00A6H <LSB>
Voltage 2
00A7H <MSB>
00A8H <LSB>
Voltage 3
00A9H <MSB>
00AAH <LSB>
Voltage average
00ABH <MSB>
00ACH <LSB>
Line voltage 1-2
00ADH <MSB>
00AEH <LSB>
Line voltage 2-3
00AFH <MSB>
00B0H <LSB>
Line voltage 3-1
00B1H <MSB>
00B2H <LSB>
Line voltage average
00B3H <MSB>
00B4H <LSB>
Current (1)
00B5H <MSB>
00B6H <LSB>
Current (2)
00B7H <MSB>
00B8H <LSB>
Current (3)
00B9H <MSB>
00BCH <LSB>
Current average
00BDH <MSB>
00BEH
Frequency (1)
00BFH
Frequency (2)
00C0H
Frequency (3)
00C1H
Frequency average
00C2H
PF (1)
00C3H
PF (2)
00C4H
PF (3)
00C5H
PF average
* 'Range' is not the measurement range, it shows the data range.
Name
Unit
0.01kW
0.01kW
0.01kW
0.01kW
0.01kvar
0.01kvar
0.01kvar
0.01kvar
0.01kVA
0.01kVA
0.01kVA
0.01kVA
0.1V
0.1V
0.1V
0.1V
0.1V
0.1V
0.1V
0.1V
0.01A
0.01A
0.01A
0.01A
0.1Hz
0.1Hz
0.1Hz
0.1Hz
0.001
0.001
0.001
0.001
Kind of data
Range: Hexadecimal
Signed 32bit
FA0A1F01H to 5F5E0FFH
Signed 32bit
FA0A1F01H to 5F5E0FFH
Signed 32bit
FA0A1F01H to 5F5E0FFH
Signed 32bit
EE1E5D03H to 11E1A2FDH
Signed 32bit
FA0A1F01H to 5F5E0FFH
Signed 32bit
FA0A1F01H to 5F5E0FFH
Signed 32bit
FA0A1F01H to 5F5E0FFH
Signed 32bit
EE1E5D03H to 11E1A2FDH
Unsigned
0H to 5F5E0FFH
32bit
Unsigned
0H to 5F5E0FFH
32bit
Unsigned
0H to 5F5E0FFH
32bit
Unsigned
0H to 11E1A2FDH
32bit
Unsigned
0H to 3B9AC9FFH
32bit
Unsigned
0H to 3B9AC9FFH
32bit
Unsigned
0H to 3B9AC9FFH
32bit
Unsigned
0H to 3B9AC9FFH
32bit
Unsigned
0H to 3B9AC9FFH
32bit
Unsigned
0H to 3B9AC9FFH
32bit
Unsigned
0H to 3B9AC9FFH
32bit
Unsigned
0H to 3B9AC9FFH
32bit
Unsigned
0H to 3B9AC9FFH
32bit
Unsigned
0H to 3B9AC9FFH
32bit
Unsigned
0H to 3B9AC9FFH
32bit
Unsigned
0H to 3B9AC9FFH
32bit
Unsigned
0H to 3E8H
16bit
Unsigned
0H to 3E8H
16bit
Unsigned
0H to 3E8H
16bit
Unsigned
0H to 3E8H
16bit
Signed 16bit
FC18H to 3E8H
Signed 16bit
FC18H to 3E8H
Signed 16bit
FC18H to 3E8H
Signed 16bit
FC18H to 3E8H
53
KW9M Eco-POWER METER
Function
code
03H
03H
03H
03H
03H
03H
03H
03H
03H
03H
03H
03H
03H
03H
03H
03H
03H
03H
03H
03H
03H
03H
03H
03H
03H
03H
03H
03H
03H
03H
03H
03H

Advertisement

Table of Contents
loading

Table of Contents