Head Angle Adjustment - Bowens XMS Studio Flash User Manual

Table of Contents

Advertisement

Quick Start Guide
Stand Mounting
1.
Pull the Angle Adjustment Lever away from the main unit and extract the Stand
Mount from the recess.
2.
Push the Angle Adjustment Lever back in place to lock the Stand Mount in position.
3.
Loosen the Stand Mount Thumb Screw on the Stand Mount and place the unit onto a
support stand.
4.
Rotate the unit into the desired position and fasten in place by tightening the Thumb
Screw.

Head Angle Adjustment

1.
Pull the Angle Adjustment Lever away from the unit to unlock the Angle Adjustment
mechanism (making sure to hold the handle) and position as required.
2.
Once in position close the Angle Adjustment Lever to lock and secure in place.
Reflector/Modifier Mounting
1.
Engage the modifier with the slots in the S-mount then rotate clockwise until the
spring mounts click and lock the modifier in place.
2.
To remove a modifier, pull the Accesory Release latch away from the front end of the
unit, then turn the modifier anti-clockwise and pull away from the XMS.
Umbrella Mounting
1.
Slide the umbrella shaft into the umbrella bracket and secure in position using the
thumb screw.
Power Connection
1.
The unit should be connected to a suitably rated 95-130V AC or 195-265V AC, 50-60
Hz supply and will automatically adapt to the voltage and frequency. A suitably rated
DC/Mains Inverter may also be used.
2.
Ensure that an appropriately rated modelling lamp is fitted according to the voltage
range being used. Refer to the Specification and the User Maintenance section.
3.
Connect the power cable to the Power Input on the unit and to the power supply
outlet.
4.
Switch on the power supply.
5.
The Standby indicator should be lit, indicating that the unit is connected to the power
supply and is in Standby mode. This depends on the user option Power Switch
State setting - see below.
Turning the Unit On
1.
Press the On/Standby button.
2.
The Standby indicator will be extinguished and the Power indicator will light up
together with ALL other indicators for a period of 3 seconds. After this the indicators
will change to show the last used setting. The defaults are SYNC = CELL OFF /
MODELLING = PROP OFF / INDICATION = BEEP OFF.
3.
A user option is available (Power Switch State) to remember if the unit was on or in
standby mode if power is lost (see page 18). This ensures that the unit reverts to the
last state when power is restored.
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents