User Options

14
User Menu
Use the MENU button to access various settings to allow function customisation of the unit.
Review and Adjustment
1.
Select the required option by pressing the MENU button. Hold the MENU button down
to advance quickly through the options.
2.
Release the button when the desired option is displayed.
3.
The displayed option will be shown alternating with its value.
4.
Review or change the option value as required by using the Rotary Control. The value will
remain displayed while being changed.
5.
If no adjustment is made for approximately 10 seconds the menu mode will exit
automatically. Alternatively, press and release the TEST button to exit immediately. In
both cases any changes made will be saved.
6.
While in options mode the MODELLING, READY, SYNC and TEST functions are
disabled from their normal operation in order to prevent inadvertent changes being
made.
The following table is a summary of the options available:
OPTION
Pairing
Remote Channel
Remote Group
Pre-Flash Number
Pre-Flash Time
Pre-Flash Delay
Audible Ready Period
Sounder Function
Lamp Saver
Battery Saver
Power Switch State
Options Defaults
DISPLAY
VALUES
Pr
nP = New Pair
UP = Un-Pair
CP = Clear ALL Pairs
Ch
1 to 16
Gr
1 to 9
Pn
0 = Auto count, 1 to 10 flashes inc. main.
Pt
0.5 or 1 to 8 seconds.
Pd
0 to 15ms
Au
15 to 90 x 10 (150ms to 900ms in 50ms steps)
So
0 = Off (except READY if enabled)
1 = Warnings only
2 = Button clicks only
3 = Warnings and button clicks
LS
0 = Off, or 1 to 99 minutes
bS
0 = Off, or 1 to 15 minutes
PS
0 = Do not save, 1 = Save
0 = Keep current settings, 1 = Set defaults (does
dF
not affect radio pairing)
DEFAULT
nP
1
1
1
2.0
2
35
0
0
0
0
0