Pisector GS08 User Manual

Gsm cellular wireless alarm system
Hide thumbs Also See for GS08:

Advertisement

PiSector GSM Cellular
Wireless Alarm System
User Manual ( GS08 )
Read manual fully before use.
PiSector Inc., USA,
www.pisector.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GS08 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Pisector GS08

  • Page 1 PiSector GSM Cellular Wireless Alarm System User Manual ( GS08 ) Read manual fully before use. PiSector Inc., USA, www.pisector.com...
  • Page 2 This guide will walk you through the easy set up of your PiSECTOR system. Your system has already been customized and tuned, so everything is ready to go when you open the box.
  • Page 3: Function Keys

    System Components Console Panel Program: press this key then input password, you will enter program status (default password 888888 ) Arm: press this key and input password, you can activate your system as Away from home Disarm: press this key and input password, you can deactivate your system Chime: press this key, you will see icon...
  • Page 4: Keychain Remote

    Connect your home telephone to TEL port on back of console. Route the phone cord through the channel toward the side of the console (if you have no landline, you can use OBi110 / MagicJack / Vonage / Ooma VoIP service to connect your Internet router / modem, then connect console to the VoIP device) Note: If you use only a landline, you cannot dial out via the console, you will need to use your home phone to...
  • Page 5 Record Owner Name, then press Enter and record a voice for this remote keychain. Note: Each time you press Add, follow steps above. You can add one remote and a maximum of 8 Keychain Remotes. Edit Select Edit, press Enter to find the name of the remote, then press Enter again, you can edit the remote keychain name or record a voice for the remote keychain.
  • Page 6 immediately triggering the system. System default delay alarm time is 45 seconds. You can change this time by going to "System Settings" to set the Alarm Delay time. Siren Enable Highlight it, press Enter, Default is YES, ( if set NO, siren will disable when this zone triggered, no siren alarm will sound Note: All zones are instant zones by Default.
  • Page 7 Program and Mount Motion Sensors: Prepare Motion Sensor Separate the front and back covers of the Motion Sensor by pressing the tab with your finger or the tip of a pen (Figure A and B). B. Remove insulating paper from the battery and CLOSE the cover. The sensor needs 1-3 minutes to initialize itself.
  • Page 8 (A) the 20-second waiting period since the last trigger has not expired, or (B) the Motion Sensor is not in communication with the PiSECTOR system main console. If you want to re-start the initialization again, open the Front Cover and remove battery. Wait 5 seconds before re-installing the battery.
  • Page 9: Detection Patterns

    Detection Patterns Motion sensor Specifications Replacement Battery: CR123A Mounting Height: 6.5-7.0 feet Range: Approximately 40 feet with 90-degree vertical field of view and a 110-degree field of view in the horizontal plane...
  • Page 10: Wireless Sirens

    Wireless Sirens Plug the siren into wall outlet, then press PROGRAM key on console. Enter the default password 888888. Use scroll key to select Wireless Sirens, press ENTER, you will see the following menu: If you received a pre-programed system kit, please ignore this step and do not program it again.
  • Page 11: Sms Numbers

    Add Contact Phone Numbers Press PROGRAM key on console. Enter the default password 888888. Use scroll key to select Phone Numbers, press Enter, you will see the following menu: Select Add, press Enter. You will see Input Phone Number. Directly input your area code and phone number, press Save.
  • Page 12: Daily Schedule

    Monitoring Center Number Select and press Enter. Then select Add to add your monitoring center telephone number. ADEMCO Contact ID Select and press Enter then select Add to add your monitoring company account number. Select Delete to delete your account number. Select ADEMCO Contact ID then press Enter to select the protocol ID according to your monitoring center protocol ID request.
  • Page 13 Production Date: press Enter you will see the producing time of your system Manufacture By Pisector Inc. IMEI: press Enter you can find IMEI number for your system, maybe request to active your SIM card Remotely Control Your Home Security Alarm System Dial the number of the main unit console panel by your cell phone, and after 1 ring, you will hear a voice prompt “Please enter...
  • Page 14 Extra Wireless Keypad Instruction ( option) Model: WKP-03 This keypad does not work alone. You need to program it with PiSector Alarm Systems. It supports System model GS07, GS08, PS03 series systems.
  • Page 15: Package Includes

    At the end press Chime key to exit setting status. Delete RFID key chains from your PiSector Keypad During system disarm status, you can press default password 1 2 3 4 5 6 followed by Enter key. You will see Set indicator light on and Enter key flashing.
  • Page 16: Wireless Encryption

    be closed and system still be in arm status. Wireless Encryption If you had a neighbor having the same system or other devices that interfere your system and always results in false alarm, then during system disarm status, press default password 1 2 3 4 5 6 followed by Enter key. When you see Set indicator light on and Enter key flashing, press 4 0 + dddd (any 4 digits pass code --- you do not need to remember this pass code it is only for encrypting the system with other device) Change Password...

Table of Contents